In-vivo monitoring of patient's cardiac mechanics via seismocardiogram was recently introduced (demonstrated). Usually, seismocardiogram is recorded using accelerometers placed on patient's sternum. This study present the ability of a PVDF piezo film transducer to record the mechanical activity of the heart (seismocardiogram and heart sounds) and also of the respiration-related, thorax motion. The transducer was positioned on patient's sternum and held in position by a chest strap. Patient's ECG signal was simultaneously recorded to provide a timereference of the cardiac activity. The piezoelectric sensor was able to record respiratory movements, seismocardiogram and heart sounds: These signals can be obtained from the recorded signal by applying simple filters. The seismocardiogram waveform appears to be dependent on the various phases of the respiratory cycle. The recorded signal from the sole piezoelectric sensor can provide relevant information such heart rate, respiratory rate, timing of mechanical event within the cardiac cycle, etc.

Monitoring of respiration, seismocardiogram and heart sounds by a PVDF piezo film sensor

Clemente Fabrizio;
2014

Abstract

In-vivo monitoring of patient's cardiac mechanics via seismocardiogram was recently introduced (demonstrated). Usually, seismocardiogram is recorded using accelerometers placed on patient's sternum. This study present the ability of a PVDF piezo film transducer to record the mechanical activity of the heart (seismocardiogram and heart sounds) and also of the respiration-related, thorax motion. The transducer was positioned on patient's sternum and held in position by a chest strap. Patient's ECG signal was simultaneously recorded to provide a timereference of the cardiac activity. The piezoelectric sensor was able to record respiratory movements, seismocardiogram and heart sounds: These signals can be obtained from the recorded signal by applying simple filters. The seismocardiogram waveform appears to be dependent on the various phases of the respiratory cycle. The recorded signal from the sole piezoelectric sensor can provide relevant information such heart rate, respiratory rate, timing of mechanical event within the cardiac cycle, etc.
2014
Istituto di Biostrutture e Bioimmagini - IBB - Sede Napoli
Inglese
20th IMEKO TC4 Symposium on Measurements of Electrical Quantities: Research on Electrical and Electronic Measurement for the Economic Upturn, Together with 18th TC4 International Workshop on ADC and DCA Modeling and Testing, IWADC 2014
786
789
4
9789299007327
http://www.scopus.com/record/display.url?eid=2-s2.0-84918815588&origin=inward
September 15-17, 2014
Benevento - Italy
7
none
Bifulco, Paolo; Gargiulo Gaetano, D; D'Angelo, Giovanni; Liccardo, Annalisa; Romanò Maria, Fiammetta; Clemente, Fabrizio; Cesarelli, Mario...espandi
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/258528
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? ND
social impact