This paper deals with the investigation of the performance and limitations of the GPR method when used to map contamination plumes, and in performing 4D (time and space) monitoring of the diffusion of the oil in the subsurface. In particular, a controlled experiment carried out in the laboratory at the University of Sao Paulo (USP), Brazil, is presented. The experiment used GPR to monitor in 4D a controlled Light Non-Aqueous Phase Liquid (LNAPL) spill in a masonry tank In particular, the study has simulated a highly polluting LNAPL spill, usually occurring in electric power stations and distribution substations. The experimental results were supported by FDTD numerical simulations, which helped in characterizing the GPR signal propagation in the investigated scenario. The interesting results showed that the mapping of the contaminant plume by LNAPL spill in a substation is possible when the subsurface is saturated with water, and this opens new scenarios in environmental monitoring by GPR. (C) 2014 Elsevier B.V. All rights reserved.

GPR-4D monitoring a controlled LNAPL spill in a masonry tank at USP, Brazil

Soldovieri Francesco;Catapano Ilaria
2014

Abstract

This paper deals with the investigation of the performance and limitations of the GPR method when used to map contamination plumes, and in performing 4D (time and space) monitoring of the diffusion of the oil in the subsurface. In particular, a controlled experiment carried out in the laboratory at the University of Sao Paulo (USP), Brazil, is presented. The experiment used GPR to monitor in 4D a controlled Light Non-Aqueous Phase Liquid (LNAPL) spill in a masonry tank In particular, the study has simulated a highly polluting LNAPL spill, usually occurring in electric power stations and distribution substations. The experimental results were supported by FDTD numerical simulations, which helped in characterizing the GPR signal propagation in the investigated scenario. The interesting results showed that the mapping of the contaminant plume by LNAPL spill in a substation is possible when the subsurface is saturated with water, and this opens new scenarios in environmental monitoring by GPR. (C) 2014 Elsevier B.V. All rights reserved.
2014
Istituto per il Rilevamento Elettromagnetico dell'Ambiente - IREA
GPR
FDTD modeling
LNAPL spill
Masonry tank experiment
USP
Brazil
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/259758
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 20
social impact