Two families of aldols, obtained from the condensation of aromatic aldehydes with cyclohexanone or acetone (ten examples in each group), were analysed by high performance liquid chromatography in normal phase elution mode on three polysaccharide-based chiral stationary phases of the Lux serie, namely Lux Cellulose-2, Lux Cellulose-4 and LuxAmylose-2, which share the common feature of chlorinated substituents in the chiral selectors. Following simple optimization steps, the enantioseparation of all aldols derived from cyclohexanone was achieved and the highest values of separation factor alpha, 1.32 < alpha< 2.20) and resolution (Rs, 4.5 < Rs <17.2) were observed on Lux Cellulose-2, with the only exception of the 4-nitro-substituted derivative that was better resolved on Lux Cellulose-4. On the contrary, Lux Amylose-2 was the best choice for aldols derived from acetone and only specific analytes in this group were resolved on the cellulose-based supports. A variable-temperature study of selected compounds allowed us to determine thermodynamic parameters of the enantioseparation process, which was enthalpy-controlled in all the cases except one.

Enantioseparation of aldols by high performance liquid chromatography on polysaccharide-based chiral stationary phases that bear chlorinated substituents

Sonia Pedotti;Angela Patti
2014

Abstract

Two families of aldols, obtained from the condensation of aromatic aldehydes with cyclohexanone or acetone (ten examples in each group), were analysed by high performance liquid chromatography in normal phase elution mode on three polysaccharide-based chiral stationary phases of the Lux serie, namely Lux Cellulose-2, Lux Cellulose-4 and LuxAmylose-2, which share the common feature of chlorinated substituents in the chiral selectors. Following simple optimization steps, the enantioseparation of all aldols derived from cyclohexanone was achieved and the highest values of separation factor alpha, 1.32 < alpha< 2.20) and resolution (Rs, 4.5 < Rs <17.2) were observed on Lux Cellulose-2, with the only exception of the 4-nitro-substituted derivative that was better resolved on Lux Cellulose-4. On the contrary, Lux Amylose-2 was the best choice for aldols derived from acetone and only specific analytes in this group were resolved on the cellulose-based supports. A variable-temperature study of selected compounds allowed us to determine thermodynamic parameters of the enantioseparation process, which was enthalpy-controlled in all the cases except one.
2014
Istituto di Chimica Biomolecolare - ICB - Sede Pozzuoli
aldols
enantioseparation
high performance liquid chromatography
polysaccharide-based selectors
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/260039
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact