A method based on the coupling of HPLC with ICP-MS with an on-line pre-concentration micro-column has been developed for the analysis of inorganic and methyl mercury in the dissolved phase of natural waters. This method allows the rapid pre-concentration and matrix removal of interferences in complex matrices such as seawater with minimal sampling handling. Detection limits of 0.07 ng L -1 for inorganic mercury and 0.02 ng L -1 for methyl mercury have been achieved allowing the determination of inorganic mercury and methyl mercury in filtered seawater from the Venice lagoon. Good accuracy and reproducibility was demonstrated by the repeat analysis of the certified reference material BCR-579 coastal seawater. The developed HPLC separation was shown to be also suitable for the determination of methyl mercury in extracts of the particulate phase.

Speciation analysis of mercury in seawater from the lagoon of Venice by on-line pre-concentration HPLC-ICP-MS

Cairns;Turetta C;Barbante;
2008

Abstract

A method based on the coupling of HPLC with ICP-MS with an on-line pre-concentration micro-column has been developed for the analysis of inorganic and methyl mercury in the dissolved phase of natural waters. This method allows the rapid pre-concentration and matrix removal of interferences in complex matrices such as seawater with minimal sampling handling. Detection limits of 0.07 ng L -1 for inorganic mercury and 0.02 ng L -1 for methyl mercury have been achieved allowing the determination of inorganic mercury and methyl mercury in filtered seawater from the Venice lagoon. Good accuracy and reproducibility was demonstrated by the repeat analysis of the certified reference material BCR-579 coastal seawater. The developed HPLC separation was shown to be also suitable for the determination of methyl mercury in extracts of the particulate phase.
2008
Istituto per la Dinamica dei Processi Ambientali - IDPA - Sede Venezia
Inductively coupled plasma
Inductively coupled plasma mass spectrometry
Mass spectrometers
Mercury (metal)
Microfluidics
Seawater
Complex matrices
Detection limit (DL)
HPLC ICP MS
Lagoon of venice
Matrix-removal
Mercury(III)
Methyl mercury (MeHg)
Natural waters
On line pre concentration
Pre concentration
Speciation analysis
Matrix algebra
mercury
methylmercury
sea water
article
atomic emission spectrometry
calibration
diagnostic accuracy
filtration
heavy metal removal
high performance liquid chromatography
nonhuman
online analysis
priority journal
process optimization
reproducibility
seashore
species differentiation
water analysis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/260969
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 51
  • ???jsp.display-item.citation.isi??? ND
social impact