he latest generation SR sources have severe constraints for the stability of the delivered radiation. The high brightness beamlines using undulator radiation are most sensitive to electron beam oscillations. Therefore, photon beam position monitors for undulator radiation are being built as detectors of beam movement and as references for feedback systems. A significant part of the radiation coming from the upstream and downstream dipoles is superimposed on the undulator radiation. A novel detector, incorporating photoelectron analysers, has been developed at Elettra. It can be tuned to the working energy of the undulator from few eV to some keV, the active elements intercepting the tails of the photon distribution. A prototype has been developed for the vertical photon beam position monitoring, and a complete set of characterisation measurements has been performed down to the lowest photon energies of the undulator peak. A description of the detector and its features are presented along with the commissioning results. (

First results of the novel photon beam position monitor for undulator beamlines of Elettra

G Paolicelli;
2001

Abstract

he latest generation SR sources have severe constraints for the stability of the delivered radiation. The high brightness beamlines using undulator radiation are most sensitive to electron beam oscillations. Therefore, photon beam position monitors for undulator radiation are being built as detectors of beam movement and as references for feedback systems. A significant part of the radiation coming from the upstream and downstream dipoles is superimposed on the undulator radiation. A novel detector, incorporating photoelectron analysers, has been developed at Elettra. It can be tuned to the working energy of the undulator from few eV to some keV, the active elements intercepting the tails of the photon distribution. A prototype has been developed for the vertical photon beam position monitoring, and a complete set of characterisation measurements has been performed down to the lowest photon energies of the undulator peak. A description of the detector and its features are presented along with the commissioning results. (
2001
Inglese
467
221
225
Sì, ma tipo non specificato
Le affiliazioni corrette sono riportate nell'Erratum : First results of the novel photon beam position monitor for undulator beamlines of Elettra (vol 467, pg 221, 2001) NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT Volume: 480 Issue: 2-3 Pages: 828-828 Article Number: PII S0168-9002(01)02181-7 DOI: 10.1016/S0168-9002(01)02181-7 Published: MAR 21 2002
6
info:eu-repo/semantics/article
262
Galimberti, A; Borghes, R; Paolucci, G; Presacco, R; Paolicelli, G; Stefani, G
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/2692
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 3
social impact