In this work laser-induced breakdown spectrosopy is implemented on aerosol particles for absolute concentration analysis. Aim of this work is the investigation of the effect of the bath gas used for nebulizing the aerosol. Nitrogen, air and 50% O2 in N2 mixture have been chosen as carrier gases in order to analyze the effect of oxygen addition to the gas. LIBS measurements have been carried out on aerosol particles produced from CuCl2 2H2O solutions, and the 324.7 nm Cu line is considered. As a first analysis, plasma parameters, such as temperature and electron density, have been evaluated changing the carrier gas. Measurements to derive the LIBS calibration curve of the 324.7 nm Cu line are carried out in air and in N2. The significant difference in the slope of the resulting calibration curves has to be attributed to the oxygen addition to the bath gas. To explore such behavior, time-resolved measurements of the Cu line and peak/base ratio have been performed. The presence of two competitive effects have been observed that becomes significant increasing the amount of oxygen in the carrier gas. One is the oxygen quenching effect, already observed in the literature, and the other one is the enhancement of the Cu LIBS signal, expecially at short delay times. These effects have been observed also at other Cu lines and changing the analyte source. The results are presented and widely discussed.

Influence of oxygen addition to the carrier gas on Laser-Induced Breakdown Spectroscopy measurements on aerosols

Palazzo N;Migliorini F;Maffi S;De Iuliis S
2016

Abstract

In this work laser-induced breakdown spectrosopy is implemented on aerosol particles for absolute concentration analysis. Aim of this work is the investigation of the effect of the bath gas used for nebulizing the aerosol. Nitrogen, air and 50% O2 in N2 mixture have been chosen as carrier gases in order to analyze the effect of oxygen addition to the gas. LIBS measurements have been carried out on aerosol particles produced from CuCl2 2H2O solutions, and the 324.7 nm Cu line is considered. As a first analysis, plasma parameters, such as temperature and electron density, have been evaluated changing the carrier gas. Measurements to derive the LIBS calibration curve of the 324.7 nm Cu line are carried out in air and in N2. The significant difference in the slope of the resulting calibration curves has to be attributed to the oxygen addition to the bath gas. To explore such behavior, time-resolved measurements of the Cu line and peak/base ratio have been performed. The presence of two competitive effects have been observed that becomes significant increasing the amount of oxygen in the carrier gas. One is the oxygen quenching effect, already observed in the literature, and the other one is the enhancement of the Cu LIBS signal, expecially at short delay times. These effects have been observed also at other Cu lines and changing the analyte source. The results are presented and widely discussed.
2016
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
Laser-Induced Breakdown Spectroscopy
Spectrochemical analysis
Cu analyte
carrier gas interference
File in questo prodotto:
File Dimensione Formato  
prod_336000-doc_107101.pdf

solo utenti autorizzati

Descrizione: Influence of oxygen addition to the carrier gas on laser-induced breakdown spectroscopy measurements on aerosols
Tipologia: Versione Editoriale (PDF)
Dimensione 755.03 kB
Formato Adobe PDF
755.03 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
prod_336000-doc_186485.pdf

accesso aperto

Descrizione: Influence of oxygen addition to the carrier gas on laser-induced breakdown spectroscopy measurements on aerosols
Tipologia: Versione Editoriale (PDF)
Dimensione 726.82 kB
Formato Adobe PDF
726.82 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/269865
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact