In this article, we show experimental results of time-resolved optical spectroscopy performed with small distance between launching and detecting fibers. It was already demonstrated that depth discrimination is independent of source-detector separation and that measurements at small source detector distance provide better contrast and spatial resolution. The main disadvantage is represent by the huge increase in early photons (scarcely diffused by tissue) peak that can saturate the dynamic range of most detectors, hiding information carried by late photons. Thanks to a fast-gated Single- Photon Avalanche Diode (SPAD) module, we are able to reject the peak of early photons and to obtain high-dynamic range acquisitions. We exploit fast-gated SPAD module to perform for the first time functional near-infrared spectroscopy (fNIRS) at small source-detector distance for in vivo measurements and we demonstrate the possibility to detect non-invasively the dynamics of oxygenated and deoxygenated haemoglobin occurring in the motor cortex during a motor task. We also show the improvement in terms of signal amplitude and Signal-to-Noise Ratio (SNR) obtained exploiting fast-gated SPAD performances with respect to "non-gated" measurements. © 2013 OSA-SPIE.

Functional near-infrared spectroscopy at small source-detector distance by means of high dynamic-range fast-gated SPAD acquisitions: First in-vivo measurements

Spinelli L;Cubeddu R;Pifferi A
2013

Abstract

In this article, we show experimental results of time-resolved optical spectroscopy performed with small distance between launching and detecting fibers. It was already demonstrated that depth discrimination is independent of source-detector separation and that measurements at small source detector distance provide better contrast and spatial resolution. The main disadvantage is represent by the huge increase in early photons (scarcely diffused by tissue) peak that can saturate the dynamic range of most detectors, hiding information carried by late photons. Thanks to a fast-gated Single- Photon Avalanche Diode (SPAD) module, we are able to reject the peak of early photons and to obtain high-dynamic range acquisitions. We exploit fast-gated SPAD module to perform for the first time functional near-infrared spectroscopy (fNIRS) at small source-detector distance for in vivo measurements and we demonstrate the possibility to detect non-invasively the dynamics of oxygenated and deoxygenated haemoglobin occurring in the motor cortex during a motor task. We also show the improvement in terms of signal amplitude and Signal-to-Noise Ratio (SNR) obtained exploiting fast-gated SPAD performances with respect to "non-gated" measurements. © 2013 OSA-SPIE.
2013
Istituto di fotonica e nanotecnologie - IFN
Functional near-infrared spectroscopy (fNIRS)
Short source-detector distance
Single-Photon Avalanche Diode
Time-Correlated Single-Photon Counting (TCSPC)
Timeresolved spectroscopy
Turbid media
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/270168
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? ND
social impact