The research of reliable substitutes of He-3 detectors is an important task for the affordability of new neutron scattering instrumentation for future spallation sources like the European Spallation Source. GEM (Gas Electron Multiplier)-based detectors represent a valid alternative since they can combine high-rate capability, coverage of up to 1 m(2) area and good intrinsic spatial resolution (for this detector class it can be better than 0.5 mm). The first neutron diffraction measurements performed using a borated GEM detector are reported. The detector has an active area of 10 x 5 cm(2) and is equipped with a borated cathode. The GEM detector was read out using the standard ISIS Data Acquisition System. The comparison with measurements performed with standard He-3 detectors shows that the broadening of the peaks measured on the diffractogram obtained with the GEM is 20-30% wider than the one obtained by He-3 tubes but the active area of the GEM is twice that of He-3 tubes. The GEM resolution is improved if half of its active area is considered. The signal-to-background ratio of the GEM is about 1.5 to 2 times lower than that of He-3. This measurement proves that GEM detectors can be used for neutron diffraction measurements and paves the way for their use at future neutron spallation sources. Copyright (C) EPLA, 2014

Diffraction measurements with a boron-based GEM neutron detector

Croci Gabriele;Cremona Anna;Grosso Giovanni;Muraro Andrea;Rebai Marica;Tardocchi Marco;Gorini Giuseppe
2014

Abstract

The research of reliable substitutes of He-3 detectors is an important task for the affordability of new neutron scattering instrumentation for future spallation sources like the European Spallation Source. GEM (Gas Electron Multiplier)-based detectors represent a valid alternative since they can combine high-rate capability, coverage of up to 1 m(2) area and good intrinsic spatial resolution (for this detector class it can be better than 0.5 mm). The first neutron diffraction measurements performed using a borated GEM detector are reported. The detector has an active area of 10 x 5 cm(2) and is equipped with a borated cathode. The GEM detector was read out using the standard ISIS Data Acquisition System. The comparison with measurements performed with standard He-3 detectors shows that the broadening of the peaks measured on the diffractogram obtained with the GEM is 20-30% wider than the one obtained by He-3 tubes but the active area of the GEM is twice that of He-3 tubes. The GEM resolution is improved if half of its active area is considered. The signal-to-background ratio of the GEM is about 1.5 to 2 times lower than that of He-3. This measurement proves that GEM detectors can be used for neutron diffraction measurements and paves the way for their use at future neutron spallation sources. Copyright (C) EPLA, 2014
2014
Istituto di fisica del plasma - IFP - Sede Milano
____
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/272124
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? ND
social impact