We report on the fabrication and preliminary characterization of novel 3D diamond devices for charged particle detection. Three dimensional detectors present mainly two advantages with respect to conventional planar and sandwich detectors for charge particles: 1) drift distance between electrodes is comparable to mean free path of photogenerated carriers in irradiated device, enabling in this way a faster response (hundreds of ps); 2) lower bias voltages are needed to obtain the electric field values necessary to achieve high charge collection efficiency conditions. A femtosecond laser (Ti:Sapphire, ? = 800 nm, 4 mJ peak energy per pulse) was employed to create arrays of conductive graphitic columns inside the bulk of a single-crystal standard grade CVD diamond. The columns far ends, on top and bottom facets of the samples, were arranged to form metallic strips, then wire-bonded to a dedicated sample holder and connected to the read-out electronics. Preliminary measurements were performed under alpha particle irradiation (241Am radioactive source, 5.5 MeV, 37 kBq), including current transient time-of-flight analysis and energy dispersive spectroscopy. In both cases, significant results were obtained in terms of response speed, time resolution and energy resolution.

Femtosecond Laser Treated 3D Diamond Detectors for Charged Particles

M Girolami;P Calvani;S Orlando;D M Trucchi
2013

Abstract

We report on the fabrication and preliminary characterization of novel 3D diamond devices for charged particle detection. Three dimensional detectors present mainly two advantages with respect to conventional planar and sandwich detectors for charge particles: 1) drift distance between electrodes is comparable to mean free path of photogenerated carriers in irradiated device, enabling in this way a faster response (hundreds of ps); 2) lower bias voltages are needed to obtain the electric field values necessary to achieve high charge collection efficiency conditions. A femtosecond laser (Ti:Sapphire, ? = 800 nm, 4 mJ peak energy per pulse) was employed to create arrays of conductive graphitic columns inside the bulk of a single-crystal standard grade CVD diamond. The columns far ends, on top and bottom facets of the samples, were arranged to form metallic strips, then wire-bonded to a dedicated sample holder and connected to the read-out electronics. Preliminary measurements were performed under alpha particle irradiation (241Am radioactive source, 5.5 MeV, 37 kBq), including current transient time-of-flight analysis and energy dispersive spectroscopy. In both cases, significant results were obtained in terms of response speed, time resolution and energy resolution.
2013
Istituto di Struttura della Materia - ISM - Sede Roma Tor Vergata
Istituto di Struttura della Materia - ISM - Sede Roma Tor Vergata
Inglese
Stefano Orlando e Salvatore Amoruso
COLA 2013 Italy - 12th International Conference on Laser Ablation - Book of Abstracts
COLA 2013 - Conference on Laser Ablation
16
16
1
978-88-908116-1-6
6-11 October 2013
Ischia (NA)
Femtosecond
Laser
none
info:eu-repo/semantics/conferenceObject
Girolami, M; Calvani, P; Orlando, S; M Trucchi, D
275
04 Contributo in convegno::04.03 Poster in Atti di convegno
4
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/277937
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact