PURPOSE: To evaluate the corneal response to variable intraocular pressure (IOP) in human eye globes after ultraviolet-A (UVA) transepithelial corneal crosslinking using iontophoresis. SETTING: Fondazione G.B. Bietti IRCCS, Rome, Italy. DESIGN: Experimental study. METHODS: Four human donor eye globes were treated with transepithelial crosslinking using iontophoresis and rapid UVA corneal irradiation, and 4 globes had standard crosslinking. Inflation experiments were performed on the globes before and after crosslinking. Topographic maps of the anterior and posterior cornea were acquired using Scheimpflug topography. Images were obtained using a mechanical regimen to analyze corneal strain in response to cyclic stress. Corneal shape changes were analyzed as a function of IOP, and corneal stress-strain curves were generated. RESULTS: Before crosslinking, instillation of hypotonic riboflavin-5-phosphate sodium 0.1% solution using iontophoresis increased corneal thickness by 5% and instillation of dextran-enriched riboflavin 0.1% solution decreased corneal thickness by 13%. Five minutes after treatment, both crosslinking procedures reduced corneal thickness by 2%. Young's modulus (E) of the anterior cornea increased by a mean of 1.8 times (from 1.6 to 2.9 MPa) and 1.9 times (from 1.3 to 2.5 MPa) after transepithelial crosslinking using iontophoresis and standard crosslinking, respectively. The E value of the posterior cornea also increased after both procedures (mean 1.7 times versus 3.1 times). CONCLUSIONS: Transepithelial crosslinking using iontophoresis increased the biomechanical strength of human corneal tissue in inflation testing of donor eye
Biomechanical changes in the human cornea after transepithelial corneal crosslinking using iontophoresis
Lombardo Giuseppe
2014
Abstract
PURPOSE: To evaluate the corneal response to variable intraocular pressure (IOP) in human eye globes after ultraviolet-A (UVA) transepithelial corneal crosslinking using iontophoresis. SETTING: Fondazione G.B. Bietti IRCCS, Rome, Italy. DESIGN: Experimental study. METHODS: Four human donor eye globes were treated with transepithelial crosslinking using iontophoresis and rapid UVA corneal irradiation, and 4 globes had standard crosslinking. Inflation experiments were performed on the globes before and after crosslinking. Topographic maps of the anterior and posterior cornea were acquired using Scheimpflug topography. Images were obtained using a mechanical regimen to analyze corneal strain in response to cyclic stress. Corneal shape changes were analyzed as a function of IOP, and corneal stress-strain curves were generated. RESULTS: Before crosslinking, instillation of hypotonic riboflavin-5-phosphate sodium 0.1% solution using iontophoresis increased corneal thickness by 5% and instillation of dextran-enriched riboflavin 0.1% solution decreased corneal thickness by 13%. Five minutes after treatment, both crosslinking procedures reduced corneal thickness by 2%. Young's modulus (E) of the anterior cornea increased by a mean of 1.8 times (from 1.6 to 2.9 MPa) and 1.9 times (from 1.3 to 2.5 MPa) after transepithelial crosslinking using iontophoresis and standard crosslinking, respectively. The E value of the posterior cornea also increased after both procedures (mean 1.7 times versus 3.1 times). CONCLUSIONS: Transepithelial crosslinking using iontophoresis increased the biomechanical strength of human corneal tissue in inflation testing of donor eye| File | Dimensione | Formato | |
|---|---|---|---|
|
prod_300978-doc_86090.pdf
accesso aperto
Descrizione: Biomechanical changes of the human cornea following transepithelial corneal cross-linking using iontophoresis
Dimensione
1.19 MB
Formato
Adobe PDF
|
1.19 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.