Halloysite Nanotubes (HNTs) are nanomaterials composed of double layered aluminosilicate minerals with a predominantly hollow tubular structure in submicron range. HNTs are characterized by a wide range of applications in anticancer therapy, sustained agent delivery, being particularly interesting because of their tunable release rates and fast adsorption rates. However systematic investigations of their acoustic properties are still poorly documented. This paper shows a quantitative assessment of the effectiveness of HNTs as scatterers at conventional ultrasonic frequencies (5.7 -7 MHz) in low range of concentrations (1.5-5 mg/mL). Different samples of HNT (diameter: 40-50 nm; length: 0.5 to 2 microns, empty lumen diameter: 15-20 nm) containing agarose gel were imaged through a commercially available echographic system and acquired data were processed through a dedicated prototypal platform in order to extract the average ultrasonic signal amplitude associated to the considered sample. Relationships have been established among backscatter, HNT concentration and the employed echographic frequency. Our results demonstrated that improvement in image backscatter could be achieved incrementing HNT concentration, determining a non-linear signal enhancement due to the fact that they are poly-disperse in length. On the other hand the effect of different echographic frequencies used was almost constant at all concentrations, specifically using higher values of echographic frequency allows yielding a signal enhanced of a factor 1.75±0.26. © 2013 IEEE.

Assessment of the enhancement potential of Halloysite Nanotubes for echographic imaging

Conversano Francesco;Casciaro Ernesto;Casciaro Sergio;Leporatti Stefano;
2013

Abstract

Halloysite Nanotubes (HNTs) are nanomaterials composed of double layered aluminosilicate minerals with a predominantly hollow tubular structure in submicron range. HNTs are characterized by a wide range of applications in anticancer therapy, sustained agent delivery, being particularly interesting because of their tunable release rates and fast adsorption rates. However systematic investigations of their acoustic properties are still poorly documented. This paper shows a quantitative assessment of the effectiveness of HNTs as scatterers at conventional ultrasonic frequencies (5.7 -7 MHz) in low range of concentrations (1.5-5 mg/mL). Different samples of HNT (diameter: 40-50 nm; length: 0.5 to 2 microns, empty lumen diameter: 15-20 nm) containing agarose gel were imaged through a commercially available echographic system and acquired data were processed through a dedicated prototypal platform in order to extract the average ultrasonic signal amplitude associated to the considered sample. Relationships have been established among backscatter, HNT concentration and the employed echographic frequency. Our results demonstrated that improvement in image backscatter could be achieved incrementing HNT concentration, determining a non-linear signal enhancement due to the fact that they are poly-disperse in length. On the other hand the effect of different echographic frequencies used was almost constant at all concentrations, specifically using higher values of echographic frequency allows yielding a signal enhanced of a factor 1.75±0.26. © 2013 IEEE.
2013
Istituto di Fisiologia Clinica - IFC
Istituto di Nanotecnologia - NANOTEC
9781467351966
halloysite nanotubes
medical imaging
molecular imaging
phantom
ultrasound
File in questo prodotto:
File Dimensione Formato  
prod_321392-doc_96023.pdf

solo utenti autorizzati

Descrizione: Articolo pubblicato
Dimensione 989.54 kB
Formato Adobe PDF
989.54 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/278870
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 12
social impact