The gamma-ray spectroscopy is a promising method for diagnosing fast ions and confined,m particles in a fusion plasma device. This application requires gamma-ray detectors with high energy resolution (say a few percent for gamma-ray energies in the range 1-5 MeV), high efficiency and high count rate capability, ideally up to a few Ml-lz. Furthermore, the detector will have to withstand the high 14 MeV and 2.45 MeV neutron fluxes produced by the main fusion reactions between deuterium and tritium. Experimental results demonstrate that the requirements on energy resolution, efficiency and count rate can be met with a LaBr3(Ce) scintillator detector equipped with fast digital data acquisition. The measured response of the detector to 2.45 MeV neutrons is presented in this paper and discussed in terms of the interaction mechanism between neutrons and detector. (C) 2013 The Authors. Published by Elsevier B.V. All rights reserved.

LaBr3 scintillator response to admixed neutron and gamma-ray fluxes

Croci G;Grosso G;Nocente M;Tardocchi M;Gorini G;
2013

Abstract

The gamma-ray spectroscopy is a promising method for diagnosing fast ions and confined,m particles in a fusion plasma device. This application requires gamma-ray detectors with high energy resolution (say a few percent for gamma-ray energies in the range 1-5 MeV), high efficiency and high count rate capability, ideally up to a few Ml-lz. Furthermore, the detector will have to withstand the high 14 MeV and 2.45 MeV neutron fluxes produced by the main fusion reactions between deuterium and tritium. Experimental results demonstrate that the requirements on energy resolution, efficiency and count rate can be met with a LaBr3(Ce) scintillator detector equipped with fast digital data acquisition. The measured response of the detector to 2.45 MeV neutrons is presented in this paper and discussed in terms of the interaction mechanism between neutrons and detector. (C) 2013 The Authors. Published by Elsevier B.V. All rights reserved.
2013
Istituto di fisica del plasma - IFP - Sede Milano
X- and gamma-ray spectroscopy
Scintillation detectors
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/279743
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact