At present, attenuation values reported on the hearing protection device (HPD) la-bel are strongly overestimated due to an evaluation method inappropriate for the envi-ronments in which they have to be used: the workplaces. An alternative test protocol was validated and published as standard. It should be transposed in the regulatory and legislative scenario and then adopted by manufacturers. Meanwhile, derating schemes proposed by NIOSH may be applied for reducing the labelled attenuation data, in spite of their roughness. Moreover, attenuation values differ from subject to subject. Especially when expo-sure levels are high or hearing loss is worsening, it could thus be necessary to evaluate the attenuation provided by the hearing protector on each worker. To overcome this problem, the assessment of the hearing threshold levels on a subject with and without the HPD could be integrated into the annual audiometry program.

Attualmente, i valori di attenuazione a corredo dei dispositivi di protezione risultano fortemente sovrastimati a causa di una procedura di determinazione incongrua per gli ambienti in cui essi vengono impiegati, ossia i luoghi di lavoro. Una procedura alterna-tiva è già stata validata ed è già oggetto di norma: andrebbe quindi recepita a livello normativo-legislativo e applicata. In attesa, i valori di attenuazione a corredo dei dispo-sitivi andrebbero corretti applicando i coefficienti proposti dal NIOSH anche se tale me-todo solleva non pochi dubbi. Sussiste inoltre il problema della variabilità dell'attenuazione dei dispositivi tra soggetto e soggetto. Nel caso di rischio uditivo elevato o di peggioramento dei deficit uditivi potrebbe essere così necessario valutare l'attenuazione del dispositivo sul singolo lavoratore. La tecnica che si basa sulla valutazione della soglia uditiva a dispositivi indossati e non indossati potrebbe essere attuata dal medico competente in occasione dell'esame audiometrico periodico.

Valutazione dell'adeguatezza dei dispositivi di protezione individuali di protezione uditiva

Francesca Pedrielli;
2010

Abstract

At present, attenuation values reported on the hearing protection device (HPD) la-bel are strongly overestimated due to an evaluation method inappropriate for the envi-ronments in which they have to be used: the workplaces. An alternative test protocol was validated and published as standard. It should be transposed in the regulatory and legislative scenario and then adopted by manufacturers. Meanwhile, derating schemes proposed by NIOSH may be applied for reducing the labelled attenuation data, in spite of their roughness. Moreover, attenuation values differ from subject to subject. Especially when expo-sure levels are high or hearing loss is worsening, it could thus be necessary to evaluate the attenuation provided by the hearing protector on each worker. To overcome this problem, the assessment of the hearing threshold levels on a subject with and without the HPD could be integrated into the annual audiometry program.
2010
Istituto per le Macchine Agricole e Movimento Terra - IMAMOTER - Sede Ferrara
Attualmente, i valori di attenuazione a corredo dei dispositivi di protezione risultano fortemente sovrastimati a causa di una procedura di determinazione incongrua per gli ambienti in cui essi vengono impiegati, ossia i luoghi di lavoro. Una procedura alterna-tiva è già stata validata ed è già oggetto di norma: andrebbe quindi recepita a livello normativo-legislativo e applicata. In attesa, i valori di attenuazione a corredo dei dispo-sitivi andrebbero corretti applicando i coefficienti proposti dal NIOSH anche se tale me-todo solleva non pochi dubbi. Sussiste inoltre il problema della variabilità dell'attenuazione dei dispositivi tra soggetto e soggetto. Nel caso di rischio uditivo elevato o di peggioramento dei deficit uditivi potrebbe essere così necessario valutare l'attenuazione del dispositivo sul singolo lavoratore. La tecnica che si basa sulla valutazione della soglia uditiva a dispositivi indossati e non indossati potrebbe essere attuata dal medico competente in occasione dell'esame audiometrico periodico.
rumore
dispositivi di protezione uditiva
attenuazione
noise
hearing protection device
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.