An UHPLC-ESI-MS/MS multi-residue method based on an on-line SPE procedure for the simultaneous determination of 9 perfluoroalkyl carboxylates (from 4 to 12 carbon atoms) and 3 perfluoroalkyl sulphonates (4, 6 and 8 carbon atoms) is described. The results of the in house validation, for 5 mL injection, showed good linearity ranges spanning two orders of magnitude between LOQ and 100 ng/L for PFUnDA and PFDoDA and LOQ and 200 ng/L for the other compounds. The percentage of recoveries, between 76 and 134%, calculated in different matrices (tap water and rivers impacted by different pollutions) were generally satisfactory. LODs and LOQs of this on-line SPE method, which also incorporate recovery losses, ranged from 0,2 to 5.0 ng/L and from 1 to 20 ng/L respectively. The linking of the sample extraction and the chromatographic analysis allows to limit the volume of sample to be collected, to reduce handling steps (centrifugation and the acidification of the sample before injection) and obtain a high-throughput analytical method to be implemented in of environmental monitoring programs.

Viene descritto un metodo UHPLC-MS, accoppiato alla pre-concentrazione in linea del campione, per la misura simultanea di composti perfluoroalchilcarbossilici da 4 a 12 atomi di carbonio e perfluoroalchilsolfonici con 4, 6 e 8 atomi di carbonio in campioni acquosi. Il metodo, che prevede l'iniezione di 5 mL di campione e la quantificazione mediante diluizione isotopica con standard marcati con isotopi stabili, è stato validato. La linearità, in un intervallo di due ordini di grandezza (tra LOQ e 100 ng / L per PFUnDA e PFDoDA e tra LOQ e 200 ng/L per gli altri composti), è risultata buona e i recuperi degli analiti in matrici reali (acqua di rubinetto e fiumi interessati da diversi inquinamenti) sono stati soddisfacenti e compresi tra il 76 e il 134%. I limiti di determinazione e di quantificazione, che comprendono anche le perdite durante l'estrazione, sono compresi tra 0,2 a 5,0 ng/L e tra 1 a 20 ng / L, rispettivamente. L'accoppiamento della fase di estrazione del campione e di analisi cromatografica permette di limitare il volume di campione da raccogliere, ridurre le fasi di manipolazione (eventuale centrifugazione e acidificazione del campione prima dell'iniezione) ed ottenere, quindi, un metodo ad alta produttività analitica da implementare nei programmi di monitoraggio ambientali.

Analisi multiresiduale LC-MS mediante arricchimento in linea del campione (on-line SPE/UHPLC-ESI-MS/MS) per la determinazione di acidi perfluoroalchilcarbossilati e perfluoroalchilsolfonati nelle acque dolci naturali

Valsecchi S;
2013

Abstract

An UHPLC-ESI-MS/MS multi-residue method based on an on-line SPE procedure for the simultaneous determination of 9 perfluoroalkyl carboxylates (from 4 to 12 carbon atoms) and 3 perfluoroalkyl sulphonates (4, 6 and 8 carbon atoms) is described. The results of the in house validation, for 5 mL injection, showed good linearity ranges spanning two orders of magnitude between LOQ and 100 ng/L for PFUnDA and PFDoDA and LOQ and 200 ng/L for the other compounds. The percentage of recoveries, between 76 and 134%, calculated in different matrices (tap water and rivers impacted by different pollutions) were generally satisfactory. LODs and LOQs of this on-line SPE method, which also incorporate recovery losses, ranged from 0,2 to 5.0 ng/L and from 1 to 20 ng/L respectively. The linking of the sample extraction and the chromatographic analysis allows to limit the volume of sample to be collected, to reduce handling steps (centrifugation and the acidification of the sample before injection) and obtain a high-throughput analytical method to be implemented in of environmental monitoring programs.
2013
Istituto di Ricerca Sulle Acque - IRSA
Viene descritto un metodo UHPLC-MS, accoppiato alla pre-concentrazione in linea del campione, per la misura simultanea di composti perfluoroalchilcarbossilici da 4 a 12 atomi di carbonio e perfluoroalchilsolfonici con 4, 6 e 8 atomi di carbonio in campioni acquosi. Il metodo, che prevede l'iniezione di 5 mL di campione e la quantificazione mediante diluizione isotopica con standard marcati con isotopi stabili, è stato validato. La linearità, in un intervallo di due ordini di grandezza (tra LOQ e 100 ng / L per PFUnDA e PFDoDA e tra LOQ e 200 ng/L per gli altri composti), è risultata buona e i recuperi degli analiti in matrici reali (acqua di rubinetto e fiumi interessati da diversi inquinamenti) sono stati soddisfacenti e compresi tra il 76 e il 134%. I limiti di determinazione e di quantificazione, che comprendono anche le perdite durante l'estrazione, sono compresi tra 0,2 a 5,0 ng/L e tra 1 a 20 ng / L, rispettivamente. L'accoppiamento della fase di estrazione del campione e di analisi cromatografica permette di limitare il volume di campione da raccogliere, ridurre le fasi di manipolazione (eventuale centrifugazione e acidificazione del campione prima dell'iniezione) ed ottenere, quindi, un metodo ad alta produttività analitica da implementare nei programmi di monitoraggio ambientali.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/284445
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact