T2n maps obtainedbytheprocessingofmultiechoMRsequencescanbeusefulinseveralclinical applications. T2n map generationproceduresshouldjoinaprocessingtimecompatiblewithon-line image analysiswithagoodprecisionintheentire T2n rangeofclinicalinterest.Fastgenerationof T2n maps canbeachievedbytheestimationofthe T2n valuesbytheweightedlinear fitting ofthelogarithm of thesignal(WLSL)method.Thisapproachfailsifthesignaldecaydivergesfromapureexponential decay,ashappensatlow T2n valueswheretherapiddecayinthesignalintensityleadstoaplateauinthe later echotimes(TE). Theproposedmethodimplementstheautomatictruncationofthesignaldecay curves tobe fitted inordertocompensateforthesignalcollapseatlow T2n values,allowingthe extensionoftheWLSLmethodthroughtheentireclinicalrangeof T2n values. Validation wasperformedonsyntheticimagesandon60thalassemiamajorpatientswithdifferent levels ofmyocardialironoverload.Phantomexperimentsshowedthata5% fitting errorthreshold representedthebestcompromisebetween T2n valuemeasurementprecisionandprocessingtime.A good agreementwasfoundbetween T2n map pixel-wisemeasurementsandROI-basedmeasurements performed byexpertreaders(CoV¼1.84%inglobalheart T2n, CoV¼5.8% insegmentalanalysis).In conclusion, thedevelopedprocedurewaseffectiveingeneratingcorrect T2n maps fortheentire T2n clinical range.

Fast generation of T2* maps in the entire range of clinical interest: Application to thalassemia major patients

Santarelli Maria Filoména;Landini Luigi;
2015

Abstract

T2n maps obtainedbytheprocessingofmultiechoMRsequencescanbeusefulinseveralclinical applications. T2n map generationproceduresshouldjoinaprocessingtimecompatiblewithon-line image analysiswithagoodprecisionintheentire T2n rangeofclinicalinterest.Fastgenerationof T2n maps canbeachievedbytheestimationofthe T2n valuesbytheweightedlinear fitting ofthelogarithm of thesignal(WLSL)method.Thisapproachfailsifthesignaldecaydivergesfromapureexponential decay,ashappensatlow T2n valueswheretherapiddecayinthesignalintensityleadstoaplateauinthe later echotimes(TE). Theproposedmethodimplementstheautomatictruncationofthesignaldecay curves tobe fitted inordertocompensateforthesignalcollapseatlow T2n values,allowingthe extensionoftheWLSLmethodthroughtheentireclinicalrangeof T2n values. Validation wasperformedonsyntheticimagesandon60thalassemiamajorpatientswithdifferent levels ofmyocardialironoverload.Phantomexperimentsshowedthata5% fitting errorthreshold representedthebestcompromisebetween T2n valuemeasurementprecisionandprocessingtime.A good agreementwasfoundbetween T2n map pixel-wisemeasurementsandROI-basedmeasurements performed byexpertreaders(CoV¼1.84%inglobalheart T2n, CoV¼5.8% insegmentalanalysis).In conclusion, thedevelopedprocedurewaseffectiveingeneratingcorrect T2n maps fortheentire T2n clinical range.
2015
Istituto di Fisiologia Clinica - IFC
Iron overload
Magnetic resonance imaging
Relaxometry
[object Object
Thalassemia
File in questo prodotto:
File Dimensione Formato  
prod_322602-doc_97066.pdf

non disponibili

Descrizione: Fast generation of T2* maps in the entire range of clinical interest: Application to thalassemia major patients
Dimensione 5.21 MB
Formato Adobe PDF
5.21 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/286754
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? ND
social impact