We assessed a method for the preparation of small, highly stable and unprotected Pd nanoparticles by picosecond laser ablation in 2-propanol. The nanoparticles can be extracted from 2-propanol by centrifugation and redispersed in water, where a strongly negative zeta-potential assures long term stability. The proposed procedure permits reduction of particle size down to 1.6 nm and optimization of the Pd(O):Pd(II) ratio which, in the best cases, was of the order of 6:1. The increase of this ratio with ablation times has been correlated to the high temperature conversion of PdO to metallic Pd by a simple theoretical model. A study of the relationship between colloid absorption at 400 nm and Pd concentration permitted the role of PdO in the determination of the UV-vis spectra to be clarified and the limits of the Mie theory for the evaluation of colloid concentration to be established. The absorption at 400 nm can be used as a fast method to estimate the Pd content in the colloids, provided that a calibration of the ablation process is preliminarily performed. (C) 2014 Elsevier Inc. All rights reserved.

Preparation of small size palladium nanoparticles by picosecond laser ablation and control of metal concentration in the colloid

E Giorgetti;
2014

Abstract

We assessed a method for the preparation of small, highly stable and unprotected Pd nanoparticles by picosecond laser ablation in 2-propanol. The nanoparticles can be extracted from 2-propanol by centrifugation and redispersed in water, where a strongly negative zeta-potential assures long term stability. The proposed procedure permits reduction of particle size down to 1.6 nm and optimization of the Pd(O):Pd(II) ratio which, in the best cases, was of the order of 6:1. The increase of this ratio with ablation times has been correlated to the high temperature conversion of PdO to metallic Pd by a simple theoretical model. A study of the relationship between colloid absorption at 400 nm and Pd concentration permitted the role of PdO in the determination of the UV-vis spectra to be clarified and the limits of the Mie theory for the evaluation of colloid concentration to be established. The absorption at 400 nm can be used as a fast method to estimate the Pd content in the colloids, provided that a calibration of the ablation process is preliminarily performed. (C) 2014 Elsevier Inc. All rights reserved.
2014
Istituto dei Sistemi Complessi - ISC
Pd nanoparticles
Laser ablation
Metal clusters
Pd oxides
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/287041
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? ND
social impact