Microwave imaging (MWI) is an emerging tool for medical diagnostics, potentially offering unique advantages such as the capability of providing quantitative images of the inspected tissues. This involves, however, solving a challenging nonlinear and ill-posed electromagnetic inverse scattering problem. This paper presents a robust method for quantitative MWI in medical applications where very little, if any, a priori information on the imaging scenario is available. This is accomplished by employing a distorted Born iterative method and a regularization by projection technique, which reconstructs the tissue parameters using a wavelet basis expansion to represent the unknown contrast. This approach is suited for any microwave medical imaging application where the requirement for increased resolution dictates the use of higher frequency data and, consequently, a robust regularization strategy. To demonstrate the robustness of the proposed approach, this paper presents reconstructions of highly heterogeneous anatomically realistic numerical breast phantoms in a canonical 2-D configuration.

Wavelet-Based Regularization for Robust Microwave Imaging in Medical Applications

Scapaticci Rosa;Crocco Lorenzo
2015

Abstract

Microwave imaging (MWI) is an emerging tool for medical diagnostics, potentially offering unique advantages such as the capability of providing quantitative images of the inspected tissues. This involves, however, solving a challenging nonlinear and ill-posed electromagnetic inverse scattering problem. This paper presents a robust method for quantitative MWI in medical applications where very little, if any, a priori information on the imaging scenario is available. This is accomplished by employing a distorted Born iterative method and a regularization by projection technique, which reconstructs the tissue parameters using a wavelet basis expansion to represent the unknown contrast. This approach is suited for any microwave medical imaging application where the requirement for increased resolution dictates the use of higher frequency data and, consequently, a robust regularization strategy. To demonstrate the robustness of the proposed approach, this paper presents reconstructions of highly heterogeneous anatomically realistic numerical breast phantoms in a canonical 2-D configuration.
2015
Istituto per il Rilevamento Elettromagnetico dell'Ambiente - IREA
electromagnetic scattering inverse problem
medical imaging
wavelet transform
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/290647
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 59
  • ???jsp.display-item.citation.isi??? ND
social impact