In this Letter, we propose the use of optical pulse coding techniques for long-range distributed sensors based on Brillouin optical time-domain analysis (BOTDA). Compared to conventional BOTDA sensors, optical coding provides a significant sensing-range enhancement, allowing for temperature and strain measurements with1mspatialresolution over 50 km of standard single-mode fiber, with an accuracy of 2.2°C/44 ??, respectively. © 2010 Optical Society of America.
Simplex-coded BOTDA fiber sensor with 1 m spatial resolution over a 50 km range
Bolognini Gabriele;
2010
Abstract
In this Letter, we propose the use of optical pulse coding techniques for long-range distributed sensors based on Brillouin optical time-domain analysis (BOTDA). Compared to conventional BOTDA sensors, optical coding provides a significant sensing-range enhancement, allowing for temperature and strain measurements with1mspatialresolution over 50 km of standard single-mode fiber, with an accuracy of 2.2°C/44 ??, respectively. © 2010 Optical Society of America.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.