A method first developed to quantify ochratoxin A in wine has been applied to the analysis of domestic and imported beers in Italy. The method uses commercial immunoaffinity columns for clean-up and high-performance liquid chromatography for quantification of the toxin. Beer was degassed, then diluted with a polyethylene glycol-sodium hydrogencarbonate solution and applied to an OchraTest immunoaffinity column. Ochratoxin A was eluted from the immunoaffinity column with methanol and quantified by reversed-phase HPLC with fluorometric detector. Average recoveries of ochratoxin A from blank beer spiked at levels from 0.04 to 1.0 ng/ml ranged from 93.8% to 100.4%, with relative standard deviations between 3.3% and 5.7%. The detection limit was 0.01 ng/ml based on a signal-to-noise ratio of 3:1. The analysis of 61 samples of domestic (10) and imported (51) beers showed ochratoxin A levels ranging from <0.01 to 0.135 ng/ml with an incidence of contamination of 50% and no substantial difference between strong and pale beers. (C) 2000 Elsevier Science B.V. All rights reserved.
Determination of ochratoxin A in domestic and imported beers in Italy by immunoaffinity clean-up and liquid chromatography
Visconti A;Pascale M;
2000
Abstract
A method first developed to quantify ochratoxin A in wine has been applied to the analysis of domestic and imported beers in Italy. The method uses commercial immunoaffinity columns for clean-up and high-performance liquid chromatography for quantification of the toxin. Beer was degassed, then diluted with a polyethylene glycol-sodium hydrogencarbonate solution and applied to an OchraTest immunoaffinity column. Ochratoxin A was eluted from the immunoaffinity column with methanol and quantified by reversed-phase HPLC with fluorometric detector. Average recoveries of ochratoxin A from blank beer spiked at levels from 0.04 to 1.0 ng/ml ranged from 93.8% to 100.4%, with relative standard deviations between 3.3% and 5.7%. The detection limit was 0.01 ng/ml based on a signal-to-noise ratio of 3:1. The analysis of 61 samples of domestic (10) and imported (51) beers showed ochratoxin A levels ranging from <0.01 to 0.135 ng/ml with an incidence of contamination of 50% and no substantial difference between strong and pale beers. (C) 2000 Elsevier Science B.V. All rights reserved.File | Dimensione | Formato | |
---|---|---|---|
prod_325191-doc_98646.pdf
solo utenti autorizzati
Descrizione: Determination of ochratoxin A in domestic and imported beers in Italy by immunoaffinity clean-up and liquid chromatography
Dimensione
72.75 kB
Formato
Adobe PDF
|
72.75 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.