The electromagnetic calorimeter for the new muon (g - 2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0-4.6 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes vs. energy, impact position, angle, and crystal wrapping. The SiPMs were gain matched using a laser-based calibration system, which also provided a stabilization procedure that allowed gain correction to a level of 10(-4) per hour. After accounting for longitudinal fluctuation losses, those crystals wrapped in a white, diffusive wrapping exhibited an energy resolution sigma/E of (13.4 +/- 0.1)% /root E/GeV, while those wrapped in a black, absorptive wrapping had (4.6 +/- 0.3)%/ root E/GeV. The white-wrapped crystals having nearly twice the total light collection display a generally wider and impact-position-dependent pulse shape owing to the dynamics of the light propagation, in comparison to the black-wrapped crystals, which have a narrower pulse shape that is insensitive to impact position.
Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout
Ferrari C;Fioretti A;Gabbanini C;
2015
Abstract
The electromagnetic calorimeter for the new muon (g - 2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0-4.6 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes vs. energy, impact position, angle, and crystal wrapping. The SiPMs were gain matched using a laser-based calibration system, which also provided a stabilization procedure that allowed gain correction to a level of 10(-4) per hour. After accounting for longitudinal fluctuation losses, those crystals wrapped in a white, diffusive wrapping exhibited an energy resolution sigma/E of (13.4 +/- 0.1)% /root E/GeV, while those wrapped in a black, absorptive wrapping had (4.6 +/- 0.3)%/ root E/GeV. The white-wrapped crystals having nearly twice the total light collection display a generally wider and impact-position-dependent pulse shape owing to the dynamics of the light propagation, in comparison to the black-wrapped crystals, which have a narrower pulse shape that is insensitive to impact position.| File | Dimensione | Formato | |
|---|---|---|---|
|
prod_326799-doc_99509.pdf
solo utenti autorizzati
Descrizione: Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
1.16 MB
Formato
Adobe PDF
|
1.16 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.