Polarimetric Thomson scattering (TS) is an alternative method for the analysis of Thomson scattering spectra in which the plasma temperature T e is determined from the depolarization of the TS radiation. This is a relativistic effect and therefore the technique is suitable only for very hot plasmas (T e > 10 keV) such as those of ITER. The practical implementation of polarimetric TS requires a method to calibrate the polarimetric response of the collection optics carrying the TS light to the detection system, and in particular to measure the additional depolarization of the TS radiation introduced by the plasma-exposed first mirror. Rotational Raman scattering of laser light from diatomic gases such as H2, D2, N2 and O2 can provide a radiation source of predictable intensity and polarization state from a well-defined volume inside the vacuum vessel and is therefore suitable for these calibrations. In this paper we discuss Raman polarimetry as a technique for the calibration of a hypothetical polarimetric TS system operating in the same conditions of the ITER core TS system and suggest two calibration methods for the measurement of the additional depolarization introduced by the plasma-exposed first mirror, and in general for calibrating the polarimetric response of the detection system.

On the calibration of polarimetric Thomson scattering by Raman polarimetry

Pasqualotto Roberto
2015

Abstract

Polarimetric Thomson scattering (TS) is an alternative method for the analysis of Thomson scattering spectra in which the plasma temperature T e is determined from the depolarization of the TS radiation. This is a relativistic effect and therefore the technique is suitable only for very hot plasmas (T e > 10 keV) such as those of ITER. The practical implementation of polarimetric TS requires a method to calibrate the polarimetric response of the collection optics carrying the TS light to the detection system, and in particular to measure the additional depolarization of the TS radiation introduced by the plasma-exposed first mirror. Rotational Raman scattering of laser light from diatomic gases such as H2, D2, N2 and O2 can provide a radiation source of predictable intensity and polarization state from a well-defined volume inside the vacuum vessel and is therefore suitable for these calibrations. In this paper we discuss Raman polarimetry as a technique for the calibration of a hypothetical polarimetric TS system operating in the same conditions of the ITER core TS system and suggest two calibration methods for the measurement of the additional depolarization introduced by the plasma-exposed first mirror, and in general for calibrating the polarimetric response of the detection system.
2015
Istituto gas ionizzati - IGI - Sede Padova
Inglese
57
12
11
http://iopscience.iop.org/article/10.1088/0741-3335/57/12/125015/meta
Sì, ma tipo non specificato
plasma diagnostics
Thomson scattering
rotational Raman scattering
Mueller matrix
Stokes polarimeter
depolarization analysis
first mirror
ITER
E-ISSN: 1361-6587; Article Number 125015;
1
info:eu-repo/semantics/article
262
Giudicotti Leonardo; Pasqualotto Roberto
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/299785
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact