Solid Oxide Fuel Cells (SOFCs) are exposed to failures due to thermal cycles and to unexpected shut downs. Effects of thermal cycles related to controlled startup and shutdown can be mitigated by appropriate start/stop strategies, but unpredictable shut down strongly damages the system, especially in anode supported cells where anode's nickel oxidation arising at fast rate over 250°C usually breaks the cell, and very fast cooling of the SOFC stack down to 250° has as consequence the thermal shock break. Recently, reverse bias current application has been proposed to protect the anode from re-oxidation. In the present work the reverse bias current approach has been applied on SOFC stacks to assess the technique.

SOFC's anode protection by bias current application: first experimental results on a short stack

G Brunaccini;M Ferraro;G Squadrito;V Antonucci
2015

Abstract

Solid Oxide Fuel Cells (SOFCs) are exposed to failures due to thermal cycles and to unexpected shut downs. Effects of thermal cycles related to controlled startup and shutdown can be mitigated by appropriate start/stop strategies, but unpredictable shut down strongly damages the system, especially in anode supported cells where anode's nickel oxidation arising at fast rate over 250°C usually breaks the cell, and very fast cooling of the SOFC stack down to 250° has as consequence the thermal shock break. Recently, reverse bias current application has been proposed to protect the anode from re-oxidation. In the present work the reverse bias current approach has been applied on SOFC stacks to assess the technique.
2015
Istituto di Tecnologie Avanzate per l'Energia - ITAE
Inglese
6th European fuel Cell Piero Lunghi Conference & Exhibition (EFC2015)
85
86
2
978-88-8286-324-1
http://www.europeanfuelcell.it/images/proceedings_EFC15_web.pdf
December 16-18, 2015
Napoli (Italy)
Solid oxide fuel cell
Reverse Bias
Ando protection
4
info:eu-repo/semantics/conferenceObject
none
274
04 Contributo in convegno::04.02 Abstract in Atti di convegno
G. Brunaccini; M. Ferraro; G. Squadrito; L. Di Giovanni ; V. Antonucci
   ASsessment of SOFC CHP systems build on the TEchnology of htceRamIX 3
   ASTERIX3
   FP7
   256764
File in questo prodotto:
Non ci sono file associati a questo prodotto.