Pervasive real-time tele-monitoring is a very helpful technology to remotely monitor the vital parameters of patients and ensure mobility of both patient and doctor. In the present paperwe describe a pervasive multi-parametric and multi-patients tele-monitoring system designed for a cardiac department of a Hospital to process and display in a graphical user interface many physiological parameters such as Electrocardiogram, Heart Rate, Breathing Rate, SpO2, Activity, Posture and Temperature. This system is able to analyse in real time all parameters for more patients simultaneously using a rule-based DSS and if any of the vital parameters goes out of its normal range, the system generates visual and sounds alerts for a well-timed medical intervention. Finally all monitored parameters are saved in EDF files that could be used for further analysis. © 2014 Taylor & Francis Group, London.

Pervasive real-time multi-parametric and multi-patient tele-monitoring System

Giovanna Sannino;Giuseppe De Pietro
2014

Abstract

Pervasive real-time tele-monitoring is a very helpful technology to remotely monitor the vital parameters of patients and ensure mobility of both patient and doctor. In the present paperwe describe a pervasive multi-parametric and multi-patients tele-monitoring system designed for a cardiac department of a Hospital to process and display in a graphical user interface many physiological parameters such as Electrocardiogram, Heart Rate, Breathing Rate, SpO2, Activity, Posture and Temperature. This system is able to analyse in real time all parameters for more patients simultaneously using a rule-based DSS and if any of the vital parameters goes out of its normal range, the system generates visual and sounds alerts for a well-timed medical intervention. Finally all monitored parameters are saved in EDF files that could be used for further analysis. © 2014 Taylor & Francis Group, London.
2014
Istituto di Calcolo e Reti ad Alte Prestazioni - ICAR
Inglese
International Conference on Information Technology and Computer Application Engineering (ITCAE 2013)
323
326
978-1-315-81328-8
http://www.scopus.com/record/display.url?eid=2-s2.0-84900405548&origin=inward
Sì, ma tipo non specificato
Aug, 27-28, 2013
HongKong
ECG
M-health
Mobile system
Software architecture
Wireless monitoring
2
none
Sannino, Giovanna; DE PIETRO, Giuseppe
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/302606
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact