The present work deals with the modelling, simulation and model validation of a biogas-fed tri-reformer followed by a solid oxide fuel cell (SOFC) for power generation, and a furnace for pre-heating of the stream entering the system. In order to predict results on a micro-scale plant, the PRO/II<sup>®</sup> software was used for the simulation of the tri-reforming process, while ad-hoc models were developed for the SOFC and the furnace. Experimental results were outlined in a previous work [Lo Faro M, Vita A, Pino L, Aricò AS. Performance evaluation of a solid oxide fuel cell coupled to an external biogas tri-reforming process. Fuel Processing Technology 2013; 115:238-45]. The overall system model was validated with the experimental data carried out with a laboratory scale equipment. The performance achieved on the simulated micro-scale plant was low, due to the modelled experimental conditions; nonetheless, the inherent flexibility of the model allows its application in the assessment of larger systems operating in real conditions.

Biogas-fed solid oxide fuel cell (SOFC) coupled to tri-reformingprocess: Modelling and simulation

Vita Antonio;Lo Faro Massimiliano;Maggio Gaetano;Pino Lidia;
2015

Abstract

The present work deals with the modelling, simulation and model validation of a biogas-fed tri-reformer followed by a solid oxide fuel cell (SOFC) for power generation, and a furnace for pre-heating of the stream entering the system. In order to predict results on a micro-scale plant, the PRO/II® software was used for the simulation of the tri-reforming process, while ad-hoc models were developed for the SOFC and the furnace. Experimental results were outlined in a previous work [Lo Faro M, Vita A, Pino L, Aricò AS. Performance evaluation of a solid oxide fuel cell coupled to an external biogas tri-reforming process. Fuel Processing Technology 2013; 115:238-45]. The overall system model was validated with the experimental data carried out with a laboratory scale equipment. The performance achieved on the simulated micro-scale plant was low, due to the modelled experimental conditions; nonetheless, the inherent flexibility of the model allows its application in the assessment of larger systems operating in real conditions.
2015
Istituto di Tecnologie Avanzate per l'Energia - ITAE
Biogas
Modelling
Plant integration
SOFC
Tri-reforming
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/303490
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 27
social impact