In this paper we present the outcome of a Round Robin test carried out to validate a proposed standard procedure to measure the acceleration produced by an hand held olive harvester. Ten independent laboratories using a custom-built device were involved. The device was developed to simulate olive tree branches as far as their interaction with the harvester sticks is concerned. Collected data were analysed according to the ISO 5725-2 procedure. Accelerations measured in three of the ten laboratories were found by a cluster analysis to be statistically different from those of the remaining seven laboratories. Based on this evidence, results from the three stray laboratories were eliminated from the final sample. Laboratory data were shown to be statistically consistent with field data in the dominant front and rear X axes as well as in the rear Z axis. No statistically significant discrepancy were found for the front and the rear acceleration vector sums, which are the quantities used to quantify the occupational exposure. The procedure developed in this Round Robin test could represent a viable basis for a future test standard for hand-held olive harvesters.

A round robin test for the hand-transmitted vibration from an olive harvester

Roberto Deboli;Christian Preti;
2016

Abstract

In this paper we present the outcome of a Round Robin test carried out to validate a proposed standard procedure to measure the acceleration produced by an hand held olive harvester. Ten independent laboratories using a custom-built device were involved. The device was developed to simulate olive tree branches as far as their interaction with the harvester sticks is concerned. Collected data were analysed according to the ISO 5725-2 procedure. Accelerations measured in three of the ten laboratories were found by a cluster analysis to be statistically different from those of the remaining seven laboratories. Based on this evidence, results from the three stray laboratories were eliminated from the final sample. Laboratory data were shown to be statistically consistent with field data in the dominant front and rear X axes as well as in the rear Z axis. No statistically significant discrepancy were found for the front and the rear acceleration vector sums, which are the quantities used to quantify the occupational exposure. The procedure developed in this Round Robin test could represent a viable basis for a future test standard for hand-held olive harvesters.
2016
Istituto per le Macchine Agricole e Movimento Terra - IMAMOTER - Sede Ferrara
Olive harvester
Hand-arm vibration
Round robin test
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/304197
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact