Pulsed neutron diffraction has been used to characterize the microscopic structure and purity of single walled carbon nanotubes samples produced by arc discharge. We employed a time of flight diffractometer whose performance in measuring the microscopic structural properties of light-mass materials is well known and recognized. The extended Q-range of the instrument allows for a direct inversion of the data to determine the radial distribution function of the carbon atoms. This is compared with the corresponding function produced by computer simulation. In addition, the absolute calibration of the neutron diffraction data evidences anomalies in the diffraction spectra of the carbon nanotubes, especially at the level of the total scattering section, that could not be observed in previous neutron scattering experiments. These are attributed to the presence of a substantial amount of spurious carbonaceous material that was not quantitatively detected with more conventional diagnostic techniques.

Structure and purity of single walled carbon nanotube samples

Giannasi A;Celli M;Zoppi M
2007

Abstract

Pulsed neutron diffraction has been used to characterize the microscopic structure and purity of single walled carbon nanotubes samples produced by arc discharge. We employed a time of flight diffractometer whose performance in measuring the microscopic structural properties of light-mass materials is well known and recognized. The extended Q-range of the instrument allows for a direct inversion of the data to determine the radial distribution function of the carbon atoms. This is compared with the corresponding function produced by computer simulation. In addition, the absolute calibration of the neutron diffraction data evidences anomalies in the diffraction spectra of the carbon nanotubes, especially at the level of the total scattering section, that could not be observed in previous neutron scattering experiments. These are attributed to the presence of a substantial amount of spurious carbonaceous material that was not quantitatively detected with more conventional diagnostic techniques.
2007
Istituto dei Sistemi Complessi - ISC
TETRAHEDRAL AMORPHOUS-CARBON; NEUTRON-SCATTERING; HYDROGEN STORAGE; DIFFRACTION; GRAPHITE
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/30705
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact