The development of a miniaturized electrochemical cell for biosensor application regards both the structuring of an array of electrodes in a fluidic chamber and their connections to the control & processing unit The sensitivity of the chronoamperometric measurement performed with the cell is increased by: (a) integrating the reference electrode on the same chip with the counter-and working-electrodes, (b) designing a specific pattern of the gold electrodes and (c) serially distributing them along the pipeline reservoir. Borosilicate glass is used as substrate for the electrodes, allowing, due to its transparency, an accurate and easy pad to pad alignment of the up-side-down chip versus a PCB soldered on a standard DIL 40 socket. This alignment is necessary to accomplish the elastomer-based-solderless electric contact, between chip and PCB. The solderless contact significantly improves both reliability and signal processing accuracy. The reservoir and its cover are micromachined out of silicone rubber respectively photosensitive glass in order to easy disassemble the fluidic chamber without any damage. Both thickness and elasticity of the photosensitive glass rend the device less brittle. A plug-in -plug-flow device with improved characteristics has been obtained with a modular structure that allows further extension of the number of electrodes.

Developing a miniaturized continuous flow electrochemical cell for biosensor applications

Pilloton R
2009

Abstract

The development of a miniaturized electrochemical cell for biosensor application regards both the structuring of an array of electrodes in a fluidic chamber and their connections to the control & processing unit The sensitivity of the chronoamperometric measurement performed with the cell is increased by: (a) integrating the reference electrode on the same chip with the counter-and working-electrodes, (b) designing a specific pattern of the gold electrodes and (c) serially distributing them along the pipeline reservoir. Borosilicate glass is used as substrate for the electrodes, allowing, due to its transparency, an accurate and easy pad to pad alignment of the up-side-down chip versus a PCB soldered on a standard DIL 40 socket. This alignment is necessary to accomplish the elastomer-based-solderless electric contact, between chip and PCB. The solderless contact significantly improves both reliability and signal processing accuracy. The reservoir and its cover are micromachined out of silicone rubber respectively photosensitive glass in order to easy disassemble the fluidic chamber without any damage. Both thickness and elasticity of the photosensitive glass rend the device less brittle. A plug-in -plug-flow device with improved characteristics has been obtained with a modular structure that allows further extension of the number of electrodes.
2009
electrochemical cell
electrodes array
chronoamperometric measurements
fluidic chamber
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/307400
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact