Cardiac magnetic resonance (CMR) is considered the gold-standard noninvasive technique for the quantification of ventricular volumes by cine-imaging and of vascular flows by velocity-encoded phase contrast (VENC). In routine CMR scans, it is common to found clinical conditions, as valve regurgitations and cardiac shunts, producing a volume overload and significant mismatch between the right and left ventricular stroke volumes (RSV and LSV). In the presence of a valve regurgitation, the volume overload involves the respective ventricular chamber, whereas in cardiac shunts, the location of the volume overload depends on the site of the anatomic defect. Moreover, when a cardiac shunt is present, pulmonary and systemic cardiac outputs are different (Qp/Qs?<?1 or Qp/Qs?>?1), whereas in the presence of valve regurgitation, Qp/Qs?=?1. Therefore, by combining the cine-imaging with the VENC technique, it is possible to investigate the cardiac physiology underlying different pathological conditions producing volume overload, and to quantify this overload (the regurgitant volume and/or shunt volume). In this report, we discussed the technical, theoretical and methodological aspects of this sort of 'virtual catheterization' by CMR, providing a simple algorithm to make the correct diagnosis.

Cardiac magnetic resonance 'virtual catheterization' for the quantification of valvular regurgitations and cardiac shunt

AitAli L;
2015

Abstract

Cardiac magnetic resonance (CMR) is considered the gold-standard noninvasive technique for the quantification of ventricular volumes by cine-imaging and of vascular flows by velocity-encoded phase contrast (VENC). In routine CMR scans, it is common to found clinical conditions, as valve regurgitations and cardiac shunts, producing a volume overload and significant mismatch between the right and left ventricular stroke volumes (RSV and LSV). In the presence of a valve regurgitation, the volume overload involves the respective ventricular chamber, whereas in cardiac shunts, the location of the volume overload depends on the site of the anatomic defect. Moreover, when a cardiac shunt is present, pulmonary and systemic cardiac outputs are different (Qp/Qs??1), whereas in the presence of valve regurgitation, Qp/Qs?=?1. Therefore, by combining the cine-imaging with the VENC technique, it is possible to investigate the cardiac physiology underlying different pathological conditions producing volume overload, and to quantify this overload (the regurgitant volume and/or shunt volume). In this report, we discussed the technical, theoretical and methodological aspects of this sort of 'virtual catheterization' by CMR, providing a simple algorithm to make the correct diagnosis.
2015
Istituto di Fisiologia Clinica - IFC
CMR
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/308555
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact