In this work the development and optimization of an impedimetric label free immunosensor for the detection of Ochratoxin A (OTA) is reported. Two antibody immobilization methods (oriented and not oriented) were compared highlighting a lower limit of detection (5 pg/ml) for the not oriented immobilization but a closer linear range in contrast to oriented anti-OTA immunosensors which showed linearity in the range of 0.01-5 ng/mL OTA. The analysis of the Atomic Force Microscopy (AFM) images showed two different nanostructures indicating that the use of oriented immobilization created a more ordered and highly dense antibody surface. Finally the oriented immunosensor was used to quantify OTA in spiked cocoa bean samples and the results were compared with those registered with competitive ELISA kit. The immunosensor was sensitive to OTA lower than 2 ?g/kg that represents the lower acceptable limit of OTA established by European legislation for the common food products.

A highly sensitive impedimetric label free immunosensor for Ochratoxin measurement in cocoa beans

Roberto Pilloton;
2016

Abstract

In this work the development and optimization of an impedimetric label free immunosensor for the detection of Ochratoxin A (OTA) is reported. Two antibody immobilization methods (oriented and not oriented) were compared highlighting a lower limit of detection (5 pg/ml) for the not oriented immobilization but a closer linear range in contrast to oriented anti-OTA immunosensors which showed linearity in the range of 0.01-5 ng/mL OTA. The analysis of the Atomic Force Microscopy (AFM) images showed two different nanostructures indicating that the use of oriented immobilization created a more ordered and highly dense antibody surface. Finally the oriented immunosensor was used to quantify OTA in spiked cocoa bean samples and the results were compared with those registered with competitive ELISA kit. The immunosensor was sensitive to OTA lower than 2 ?g/kg that represents the lower acceptable limit of OTA established by European legislation for the common food products.
2016
Istituto di Cristallografia - IC
Immunosensor; Ochratoxin A; Electrochemical Impedance Spectroscopy; Atomic Force Microscopy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/308575
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 55
  • ???jsp.display-item.citation.isi??? ND
social impact