Aim of this work was to investigate the effect of ultrasound incident frequency on the echographic contrast enhancement power of an experimental drug delivery agent, halloysite clay nanotubes (HNTs), and to determine a suitable configuration in terms of both insonification frequency and particle concentration for an effective employment as targeted contrast agent. Various HNT concentrations (range 0.25-3.00 mg/mL) were dispersed in custom-designed tissue-mimicking phantoms and exposed to different ultrasound frequencies (7-11 MHz) through a conventional clinically-available echographic device. Off-line analysis included the evaluation of both amplitude of backscattered ultrasound signals and image brightness. Amplitude of HNT-backscattered signals showed a linear increase with particle concentration, while image brightness enhancement was limited by logarithmic compression effects. On the other hand, backscatter amplitude showed significant increments with increasing ultrasound frequency up to 10 MHz, then showing a concentration-dependent behavior without further enhancements. Overall, the most effective response was found when a 10-MHz ultrasound frequency was employed to insonify HNTs at a concentration of 1.5 mg/mL. In conclusion, the present study optimized the combination of incident ultrasound frequency and HNT concentration, in order to obtain an echographic image enhancement suitable for medical applications. Future dedicated studies will assess the feasibility of automatic detection of HNTs within echographic images and their possible employment as theranostic agents.

Ultrasound Signal Enhancement of Halloysite Clay Nanotubes at Medical Diagnostic Frequencies

S Casciaro;F Conversano;P Pisani;E Casciaro;M Di Paola;R Franchini;S Leporatti;G Gigli
2015

Abstract

Aim of this work was to investigate the effect of ultrasound incident frequency on the echographic contrast enhancement power of an experimental drug delivery agent, halloysite clay nanotubes (HNTs), and to determine a suitable configuration in terms of both insonification frequency and particle concentration for an effective employment as targeted contrast agent. Various HNT concentrations (range 0.25-3.00 mg/mL) were dispersed in custom-designed tissue-mimicking phantoms and exposed to different ultrasound frequencies (7-11 MHz) through a conventional clinically-available echographic device. Off-line analysis included the evaluation of both amplitude of backscattered ultrasound signals and image brightness. Amplitude of HNT-backscattered signals showed a linear increase with particle concentration, while image brightness enhancement was limited by logarithmic compression effects. On the other hand, backscatter amplitude showed significant increments with increasing ultrasound frequency up to 10 MHz, then showing a concentration-dependent behavior without further enhancements. Overall, the most effective response was found when a 10-MHz ultrasound frequency was employed to insonify HNTs at a concentration of 1.5 mg/mL. In conclusion, the present study optimized the combination of incident ultrasound frequency and HNT concentration, in order to obtain an echographic image enhancement suitable for medical applications. Future dedicated studies will assess the feasibility of automatic detection of HNTs within echographic images and their possible employment as theranostic agents.
2015
Istituto di Fisiologia Clinica - IFC
Istituto di Nanotecnologia - NANOTEC
ultrasound contrast agents; medical image enhancement; halloysite clay nanotubes; nanoimaging
File in questo prodotto:
File Dimensione Formato  
prod_349735-doc_114219.pdf

solo utenti autorizzati

Descrizione: Proceeding pubblicato
Tipologia: Versione Editoriale (PDF)
Dimensione 1.04 MB
Formato Adobe PDF
1.04 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/310761
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact