Capillary electrochromatography (CEC) was employed for the assay of ketorolac (KT) and its known related impurities [1-hydroxy analog of ketorolac (HK), 1-keto analog of ketorolac (KK), ketorolac decarboxylated (DK)] in both drug substance and coated tablets. Detection was made at 323 nm and flufenamic acid was selected as internal standard. The experiments were performed in a 100 mum i.d. capillary packed with RP- 18 silica particles (33.0, 24.5, 23.0 cm total, effective and packed lengths, respectively). The composition of the mobile phase was optimised by changing pH of the buffer and acetonitrile (ACN) content and by addition of other organic modifiers (methanol, ethanol, isopropanol, n-propanol) in order to evaluate the effect of these factors on the method performance (efficiency, retention and resolution). The optimum mobile phase consisted of a mixture of 50 mM ammonium formate buffer pH 3.5-water-acetonitrile (10:20:70, v/v/v), while voltage and temperature were set at 30 kV and 20 degreesC, respectively. Applying these conditions, all peaks were baseline resolved and the analysis was performed in less than 9 min. Selectivity, repeatability of retention time and peak area, detection and quantitation limits, linearity and range, precision and accuracy were also investigated. R.S.D. and bias values obtained for all the anallytes were below 5% and sensitivity was satisfactory, thus the method was deemed suitable for pharmaceutical quality control. Applying the method to coated tablets, a recovery of 98.5 +/- 0.8% and an R.S.D. of 0.5% were found. (C) 2004 Elsevier B.V. All rights reserved.

Analysis of ketorolac and its related impurities by capillary electrochromatography

D'Orazio G;
2004

Abstract

Capillary electrochromatography (CEC) was employed for the assay of ketorolac (KT) and its known related impurities [1-hydroxy analog of ketorolac (HK), 1-keto analog of ketorolac (KK), ketorolac decarboxylated (DK)] in both drug substance and coated tablets. Detection was made at 323 nm and flufenamic acid was selected as internal standard. The experiments were performed in a 100 mum i.d. capillary packed with RP- 18 silica particles (33.0, 24.5, 23.0 cm total, effective and packed lengths, respectively). The composition of the mobile phase was optimised by changing pH of the buffer and acetonitrile (ACN) content and by addition of other organic modifiers (methanol, ethanol, isopropanol, n-propanol) in order to evaluate the effect of these factors on the method performance (efficiency, retention and resolution). The optimum mobile phase consisted of a mixture of 50 mM ammonium formate buffer pH 3.5-water-acetonitrile (10:20:70, v/v/v), while voltage and temperature were set at 30 kV and 20 degreesC, respectively. Applying these conditions, all peaks were baseline resolved and the analysis was performed in less than 9 min. Selectivity, repeatability of retention time and peak area, detection and quantitation limits, linearity and range, precision and accuracy were also investigated. R.S.D. and bias values obtained for all the anallytes were below 5% and sensitivity was satisfactory, thus the method was deemed suitable for pharmaceutical quality control. Applying the method to coated tablets, a recovery of 98.5 +/- 0.8% and an R.S.D. of 0.5% were found. (C) 2004 Elsevier B.V. All rights reserved.
2004
Istituto per i Sistemi Biologici - ISB (ex IMC)
electrochromatography
pharmaceutical analysis
ketorolac
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/311026
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 25
social impact