Three porous materials (Cu, a Cu-Ni alloy with 70 at.% Cu and Rh-modified Cu) have been tested as electrodes for the electroanalysis of nitrate and nitrite ions, in either neutral or basic media, using mainly a flow injection technique. Porous Cu and Cu-Ni were prepared by electrodeposition at high current density, exploiting the transient template action of hydrogen bubbles. Rh-modified Cu electrodes were obtained from porous Cu, through a galvanic displacement reaction. All materials had a linear response for both nitrates and nitrites, at concentrations up to 10<sup>-3</sup> M, at least. Sensitivities, detection limits and stability were determined. Compared with Cu, used as a benchmark, (i) Rh-modified Cu had higher sensitivity for nitrates, comparable sensitivity for nitrites, lower or comparable detection limits and overall better stability; (ii) Cu-Ni had lower sensitivity, but exhibited lower detection limits and more stable performance for most analyte/medium combinations.

Study of Cu, Cu-Ni and Rh-modified Cu porous layers as electrode materials for the electroanalysis of nitrate and nitrite ions

Comisso N;Cattarin S;Guerriero P;Mattarozzi L;Musiani M;VázquezGómez L;Verlato E
2016

Abstract

Three porous materials (Cu, a Cu-Ni alloy with 70 at.% Cu and Rh-modified Cu) have been tested as electrodes for the electroanalysis of nitrate and nitrite ions, in either neutral or basic media, using mainly a flow injection technique. Porous Cu and Cu-Ni were prepared by electrodeposition at high current density, exploiting the transient template action of hydrogen bubbles. Rh-modified Cu electrodes were obtained from porous Cu, through a galvanic displacement reaction. All materials had a linear response for both nitrates and nitrites, at concentrations up to 10-3 M, at least. Sensitivities, detection limits and stability were determined. Compared with Cu, used as a benchmark, (i) Rh-modified Cu had higher sensitivity for nitrates, comparable sensitivity for nitrites, lower or comparable detection limits and overall better stability; (ii) Cu-Ni had lower sensitivity, but exhibited lower detection limits and more stable performance for most analyte/medium combinations.
2016
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
Electrocatalysis
Electrodeposition
Flow injection
Galvanic displacement
Hydrogen template
Sensor
File in questo prodotto:
File Dimensione Formato  
prod_345091-doc_115333.pdf

solo utenti autorizzati

Descrizione: Study of Cu, Cu-Ni and Rh-modified Cu porous layers as electrode materials for the electroanalysis of nitrate and nitrite ions
Tipologia: Documento in Post-print
Dimensione 697.7 kB
Formato Adobe PDF
697.7 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
prod_345091-doc_186254.pdf

accesso aperto

Descrizione: Study of Cu, Cu-Ni and Rh-modified Cu porous layers as electrode materials for the electroanalysis of nitrate and nitrite ions
Tipologia: Documento in Post-print
Dimensione 1.16 MB
Formato Adobe PDF
1.16 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/311644
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 34
social impact