A new application of the diacetyl monoxime method for the determination of dissolved urea in seawater is presented, based on the Alpkem autoanalyzer (OI, Analytical). This system has several advantages over automated methods previously described in the literature. The urea cartridge can be easily built using nut/ferrule connections, and the external thermostatic bath is not required. The system is set up to operate at low urea concentrations (0–3 mu M urea), but it is linear up to 100 mu M urea. The sample volume needed for analysis is 0.4 ml, and the rate of analysis is 25 samples h)1. The precision of analysis (CV) of seawater samples is 2.1% at 0.50 mu M urea, and the detection limit is 0.02 mu M urea. The interference on the colorimetric measurement due to formation of Brij-35 aggregate in strongly acidic media was eliminated by substituting this wetting agent with hexadecyl–trimethyl–ammonium bromide; thus, this method is suitable for other autoanalyzer technologies that use small-diameter transmission tubes and small-sized spectrophotometric flowcells.

A new application of diacetyl monoxime method to the automated determination of dissolved urea in seawater.

Cozzi S
2004

Abstract

A new application of the diacetyl monoxime method for the determination of dissolved urea in seawater is presented, based on the Alpkem autoanalyzer (OI, Analytical). This system has several advantages over automated methods previously described in the literature. The urea cartridge can be easily built using nut/ferrule connections, and the external thermostatic bath is not required. The system is set up to operate at low urea concentrations (0–3 mu M urea), but it is linear up to 100 mu M urea. The sample volume needed for analysis is 0.4 ml, and the rate of analysis is 25 samples h)1. The precision of analysis (CV) of seawater samples is 2.1% at 0.50 mu M urea, and the detection limit is 0.02 mu M urea. The interference on the colorimetric measurement due to formation of Brij-35 aggregate in strongly acidic media was eliminated by substituting this wetting agent with hexadecyl–trimethyl–ammonium bromide; thus, this method is suitable for other autoanalyzer technologies that use small-diameter transmission tubes and small-sized spectrophotometric flowcells.
2004
Istituto di Scienze Marine - ISMAR
dissolved urea;
seawater;
autoanalyzer
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/31267
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact