Electrospray ionization was applied on calcium alkoxides studying the most suitable operative conditions fortheir detection/identification. To reach this aim, calcium methoxide and ethylate were obtained by two different synthetic pathways, in order to understand their possible different aggregation states. The reaction mixture shows the presence of a supernatant and of a precipitate poorly soluble in most organic solvents. The purpose of this preliminary study is to understand the qualitative differences between the precipitated species and the ones in solution by analyzing both of them with the same analytical method. The electrospray ionization (ES!) operating conditions (voltages, temperatures, solvents) allow not only the detection of single species but also the study of clusters present in solution. Particular attention was paid to establishing the role of ESI conditions in the formation of the detected species. Experiments performed at different sprayer voltages (1 kV, 2kV, 3 kV and 4 kV) proved that ESI does not perturbate the equilibria present in the original solution, demonstrating that the technique can be a useful tool to achieve information on this class of compounds.

Study of challenging calcium alkoxides in solution by electrospray ionization mass spectrometry (Part 1)

Peruzzo V;Tomasin P;Traldi P;Favaro M
2013

Abstract

Electrospray ionization was applied on calcium alkoxides studying the most suitable operative conditions fortheir detection/identification. To reach this aim, calcium methoxide and ethylate were obtained by two different synthetic pathways, in order to understand their possible different aggregation states. The reaction mixture shows the presence of a supernatant and of a precipitate poorly soluble in most organic solvents. The purpose of this preliminary study is to understand the qualitative differences between the precipitated species and the ones in solution by analyzing both of them with the same analytical method. The electrospray ionization (ES!) operating conditions (voltages, temperatures, solvents) allow not only the detection of single species but also the study of clusters present in solution. Particular attention was paid to establishing the role of ESI conditions in the formation of the detected species. Experiments performed at different sprayer voltages (1 kV, 2kV, 3 kV and 4 kV) proved that ESI does not perturbate the equilibria present in the original solution, demonstrating that the technique can be a useful tool to achieve information on this class of compounds.
2013
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
calcium alkoxides
solution study
mass spectrometry
ESI ionization
clusters
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/313428
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact