Aim of this paper was to assess the diagnostic accuracy of a novel ultrasound (US) approach for femoral neck densitometry. A total of 173 female patients (56-75 years) were recruited and all of them underwent a dual X-ray absorptiometry (DXA) of the proximal femur and an US scan of the same anatomical district. Acquired US data were analysed through a novel algorithm that performed a series of spectral and statistical analyses in order to calculate bone mineral density employing an innovative method. Diagnostic accuracy of US investigations was quantitatively assessed through a direct comparison with DXA results. The average diagnostic agreement resulted pretty good (85.55%), with a maximum (88.00%) in correspondence of the youngest investigated patients (56-60 y). Overall, diagnostic accuracy showed only minimal variations with patient age, indicating that the proposed approach has the potential to be effectively employable for osteoporosis diagnosis in the whole considered age interval.

Estimation of femoral neck bone mineral density by ultrasound scanning: Preliminary results and feasibility

Pisani P;Conversano F;Casciaro S
2016

Abstract

Aim of this paper was to assess the diagnostic accuracy of a novel ultrasound (US) approach for femoral neck densitometry. A total of 173 female patients (56-75 years) were recruited and all of them underwent a dual X-ray absorptiometry (DXA) of the proximal femur and an US scan of the same anatomical district. Acquired US data were analysed through a novel algorithm that performed a series of spectral and statistical analyses in order to calculate bone mineral density employing an innovative method. Diagnostic accuracy of US investigations was quantitatively assessed through a direct comparison with DXA results. The average diagnostic agreement resulted pretty good (85.55%), with a maximum (88.00%) in correspondence of the youngest investigated patients (56-60 y). Overall, diagnostic accuracy showed only minimal variations with patient age, indicating that the proposed approach has the potential to be effectively employable for osteoporosis diagnosis in the whole considered age interval.
2016
Istituto di Fisiologia Clinica - IFC
Biomedical image processing
Biomedical measurements
Biomedical signal processing
Femoral neck
Osteoporosis
Ultrasound
File in questo prodotto:
File Dimensione Formato  
prod_358557-doc_117323.pdf

solo utenti autorizzati

Descrizione: Articolo pubblicato
Tipologia: Versione Editoriale (PDF)
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/313956
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact