Lab-on-a-chip applications, such as single cell manipulation and targeted delivery of chemicals, could greatly benefit from mobile untethered microdevices able to move in fluidic environments by using magnetic fields. In this paper a magnetically driven microrobotic system enabling the controlled locomotion of objects placed at the air/liquid interface is proposed and exploited for cell manipulation. In particular authors report the design, fabrication and testing of a polymeric thin film-based magnetic microrobot (called 'FilmBot') used as a support for navigating cancer cells. By finely controlling magnetic film locomotion, it is possible to navigate the cells by exploiting their adhesion to the film without affecting their integrity. Preliminary in vitro tests demonstrated that the magnetic thin film is able to act as substrate for T24 bladder cancer cells without affecting their viability and that film locomotion can be magnetically controlled (with a magnetic field and a gradient of 6 mT and 0.6 T/m, respectively) along specific directions, with a mean speed of about 3 mm/s.

Magnetically driven microrobotic system for cancer cell manipulation

Comisso N;
2015

Abstract

Lab-on-a-chip applications, such as single cell manipulation and targeted delivery of chemicals, could greatly benefit from mobile untethered microdevices able to move in fluidic environments by using magnetic fields. In this paper a magnetically driven microrobotic system enabling the controlled locomotion of objects placed at the air/liquid interface is proposed and exploited for cell manipulation. In particular authors report the design, fabrication and testing of a polymeric thin film-based magnetic microrobot (called 'FilmBot') used as a support for navigating cancer cells. By finely controlling magnetic film locomotion, it is possible to navigate the cells by exploiting their adhesion to the film without affecting their integrity. Preliminary in vitro tests demonstrated that the magnetic thin film is able to act as substrate for T24 bladder cancer cells without affecting their viability and that film locomotion can be magnetically controlled (with a magnetic field and a gradient of 6 mT and 0.6 T/m, respectively) along specific directions, with a mean speed of about 3 mm/s.
2015
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
Inglese
37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2015
2015-November
3631
3634
9781424492718
http://ieeexplore.ieee.org/document/7319179/?reload=true
Sì, ma tipo non specificato
25-29/08/2015
Milano
thin film
Category numberCFP15EMB-ART; Code 116805
6
restricted
Lucarini, G; Iacovacci, V; Ricotti, L; Comisso, N; Dario, P; Menciassi, A
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
File Dimensione Formato  
prod_359575-doc_117998.pdf

solo utenti autorizzati

Descrizione: Magnetically driven microrobotic system for cancer cell manipulation
Tipologia: Versione Editoriale (PDF)
Dimensione 871.42 kB
Formato Adobe PDF
871.42 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/316574
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact