A microclimatic monitoring of the Longobard Temple in Cividale del Friuli, Udine (Italy), was performed between 2011 and 2012 aimed at investigating the causes of the different damage features observed in the stucco statues located in the opposite sides of west-south-west wall. The thermo-hygrometric conditions of the air close to the statues were continuously monitored for one year and the surface temperature of the statues was investigated by means of thermography. According to the results, no remarkable differences in the current microclimatic conditions measured at the two sides of the west south -west wall were found, hence the cause of the different state of conservation of the statues has to be ascribed to phenomena occurred in the past. Nevertheless, the thermo-hygrometric values measured close to the statues are not fully in compliance with respect to the ranges indicated in literature for the conservation of the stucco ornaments. (C) 2015 Elsevier Masson SAS. All rights reserved.

Microclimatic monitoring for the investigation of the different state of conservation of the stucco statues of the Longobard Temple in Cividale del Friuli (Udine, Italy)

Becherini Francesca;Bernardi Adriana;Di Tuccio Maria Concetta;Vivarelli Arianna;
2016

Abstract

A microclimatic monitoring of the Longobard Temple in Cividale del Friuli, Udine (Italy), was performed between 2011 and 2012 aimed at investigating the causes of the different damage features observed in the stucco statues located in the opposite sides of west-south-west wall. The thermo-hygrometric conditions of the air close to the statues were continuously monitored for one year and the surface temperature of the statues was investigated by means of thermography. According to the results, no remarkable differences in the current microclimatic conditions measured at the two sides of the west south -west wall were found, hence the cause of the different state of conservation of the statues has to be ascribed to phenomena occurred in the past. Nevertheless, the thermo-hygrometric values measured close to the statues are not fully in compliance with respect to the ranges indicated in literature for the conservation of the stucco ornaments. (C) 2015 Elsevier Masson SAS. All rights reserved.
2016
Istituto di Scienze dell'Atmosfera e del Clima - ISAC
Microclimatic monitoring
Stucco ornaments
Cultural heritage conservation
Longobard Temple
Degradation of works
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/317860
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact