A rapid method for the quantification of five ribonucleotides 5- monophophates (adenosine, cytidine, guanosine, inosine, uridine, 5-monophosphate), in infant formula, has been proposed using nano-LC. To separate the studied compounds, capillary columns packed with different C18-based stationary phases were investigated. All the columns tested were laboratory prepared. The experiments were performed in ion-pairing RP chromatographic mode using tetrabutylammonium hydroxide as ion-pairing reagent. The method was developed using a core-shell XB-C18 capillary column with a mobile phase consisting of 5% v/v methanol and 95% v/v 100 mM ammonium formate, pH 8, containing 20 mM tetrabutylammonium hydroxide. All compounds were baseline resolved in less than 5 min with a flow rate of 500 nL/min in isocratic elution mode. Nucleotides were detected at 260 nm. Analytical validation parameters were evaluated. The RSD values for intraday and interday repeatability for retention time and peak area were <2.4 and 4.2%, respectively. The method linearity was good (R2 < 0.9995) for the studied compounds. LOD and limit of quantitation were 0.25 and 0.50 g/mL, respectively. The method was applied to the determination of nucleotides in infant formula, subjected to a centrifugal ultrafiltration process, prior their analysis. The amounts found were in agreement to the labeled contents.

Rapid determination of nucleotides in infant formula by means of nano-liquid chromatography

S Fanali;Z Aturki
2016

Abstract

A rapid method for the quantification of five ribonucleotides 5- monophophates (adenosine, cytidine, guanosine, inosine, uridine, 5-monophosphate), in infant formula, has been proposed using nano-LC. To separate the studied compounds, capillary columns packed with different C18-based stationary phases were investigated. All the columns tested were laboratory prepared. The experiments were performed in ion-pairing RP chromatographic mode using tetrabutylammonium hydroxide as ion-pairing reagent. The method was developed using a core-shell XB-C18 capillary column with a mobile phase consisting of 5% v/v methanol and 95% v/v 100 mM ammonium formate, pH 8, containing 20 mM tetrabutylammonium hydroxide. All compounds were baseline resolved in less than 5 min with a flow rate of 500 nL/min in isocratic elution mode. Nucleotides were detected at 260 nm. Analytical validation parameters were evaluated. The RSD values for intraday and interday repeatability for retention time and peak area were <2.4 and 4.2%, respectively. The method linearity was good (R2 < 0.9995) for the studied compounds. LOD and limit of quantitation were 0.25 and 0.50 g/mL, respectively. The method was applied to the determination of nucleotides in infant formula, subjected to a centrifugal ultrafiltration process, prior their analysis. The amounts found were in agreement to the labeled contents.
2016
Istituto per i Sistemi Biologici - ISB (ex IMC)
Infant formula
Ion pair reversed-phase chromatography
Nano-LC
Nucleotide 5'-monophosphates
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/318327
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? ND
social impact