The NIO1 experiment [1], built and operated at Consorzio RFX, hosts an RF negative ion source, from which it is possible to produce a beam of maximum 130 mA in H- ions, accelerated up to 60 kV. For the preliminar tests of the extraction system the source has been operated in oxygen, whose high electronegativity allows to reach useful levels of extracted beam current. The efficiency of negative ions extraction is strongly influenced by electron density and temperature close to the Plasma Grid. To support the tests these parameters have been measured by means of the Optical Emission Spectroscopy diagnostic. This technique [2] has involved the use of an oxygen-argon mixture to produce the plasma in the source. The intensities of specific Ar I and Ar II lines have been measured along lines of sight close to the Plasma Grid, and have been interpreted with the ADAS package [3] to get the desired information. This work will describe the diagnostic hardware, the analysis method and the measured values of electron density and temperature, as function of the main source parameters (RF power, pressure, bias voltage and magnetic filter field).
Electron density and temperature in NIO1 RF source, operated in oxygen and argon
Barbisan M;Pasqualotto R;Serianni G;
2016
Abstract
The NIO1 experiment [1], built and operated at Consorzio RFX, hosts an RF negative ion source, from which it is possible to produce a beam of maximum 130 mA in H- ions, accelerated up to 60 kV. For the preliminar tests of the extraction system the source has been operated in oxygen, whose high electronegativity allows to reach useful levels of extracted beam current. The efficiency of negative ions extraction is strongly influenced by electron density and temperature close to the Plasma Grid. To support the tests these parameters have been measured by means of the Optical Emission Spectroscopy diagnostic. This technique [2] has involved the use of an oxygen-argon mixture to produce the plasma in the source. The intensities of specific Ar I and Ar II lines have been measured along lines of sight close to the Plasma Grid, and have been interpreted with the ADAS package [3] to get the desired information. This work will describe the diagnostic hardware, the analysis method and the measured values of electron density and temperature, as function of the main source parameters (RF power, pressure, bias voltage and magnetic filter field).I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.