Early diagnosis of plant virus infections before the disease symptoms appearance may represent a significant benefit in limiting disease spread by a prompt application of appropriate containment steps. We propose a label-free procedure applied on a device structure where the electrical signal transduction is evaluated via impedance spectroscopy techniques. The device consists of a droplet suspension embedding two representative purified plant viruses i.e.,Tomato mosaic virus and Turnip yellow mosaic virus,put in contact with a highly hydrophobic plasma textured silicon surface. Results show a high sensitivity of the system towards the virus particles with an interestingly low detection limit,from tens to hundreds of attomolar corresponding to pg/mL of sap,which refers,in the infection time-scale,to a concentration of virus particles in still-symptomless plants. Such a threshold limit,together with an envisaged engineering of an easily manageable device,compared to more sophisticated apparatuses,may contribute in simplifying the in-field plant virus diagnostics.

Highly sensitive and practical detection of plant viruses via electrical impedance of droplets on textured silicon-based devices

Ambrico M;Ambrico PF;Minafra A;De Stradis A;Cicco SR;Palumbo F;
2016

Abstract

Early diagnosis of plant virus infections before the disease symptoms appearance may represent a significant benefit in limiting disease spread by a prompt application of appropriate containment steps. We propose a label-free procedure applied on a device structure where the electrical signal transduction is evaluated via impedance spectroscopy techniques. The device consists of a droplet suspension embedding two representative purified plant viruses i.e.,Tomato mosaic virus and Turnip yellow mosaic virus,put in contact with a highly hydrophobic plasma textured silicon surface. Results show a high sensitivity of the system towards the virus particles with an interestingly low detection limit,from tens to hundreds of attomolar corresponding to pg/mL of sap,which refers,in the infection time-scale,to a concentration of virus particles in still-symptomless plants. Such a threshold limit,together with an envisaged engineering of an easily manageable device,compared to more sophisticated apparatuses,may contribute in simplifying the in-field plant virus diagnostics.
2016
Istituto di Nanotecnologia - NANOTEC
Istituto per la Protezione Sostenibile delle Piante - IPSP
Droplet-based device
EIS
Label-free detection
Plant viruses
Surface texturing
ToMV
TYMV
File in questo prodotto:
File Dimensione Formato  
prod_364740-doc_120266.pdf

solo utenti autorizzati

Descrizione: Ambrico et al Sensors 2016
Tipologia: Versione Editoriale (PDF)
Dimensione 3.17 MB
Formato Adobe PDF
3.17 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/328015
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact