This study was aimed at evaluating the influence of sampling procedure on the determination of uric acid and lactate in oral fluid. Samples of non-stimulated and stimulated oral fluid were collected from 22 healthy volunteers. Different frequencies of stimulation were obtained by moving a polyester swab within the mouth at 50, 100 and 150min-1. Three oral fluid samples were consecutively collected from a subgroup of 5 volunteers at a constant stimulation (70min-1) and at a self-selected pace to evaluate reproducibility.The urate concentration in oral fluid decreased with the increase of the stimulation and oral fluid flow rate (r=-0.98, p=0.01). Also, the lactate concentration was much (p=0.03, two tailed) lower in samples collected under a mild stimulation (50min-1) than in samples collected without stimulation. Nevertheless, it progressively increased at higher stimulations (100 and 150min-1). A transfer process mediated by membrane carriers (i.e. urate transporter and organic anion transporters) was hypothesized to explain these results. Finally, a reduced variability (relative standard deviation below 10%) of the urate concentration was obtained when oral fluid was sampled at constant stimulation (70min-1), but it increased remarkably (20-50%) in case of sampling at self-selected pace. Nevertheless, expressing the salivary excretion of urate as a function of time (?gmin-1), the variability of sampling procedure at self-selected pace was lower than 15%.

The effect of sampling procedures on the urate and lactate concentration in oral fluid

Bramanti E;Onor M;
2016

Abstract

This study was aimed at evaluating the influence of sampling procedure on the determination of uric acid and lactate in oral fluid. Samples of non-stimulated and stimulated oral fluid were collected from 22 healthy volunteers. Different frequencies of stimulation were obtained by moving a polyester swab within the mouth at 50, 100 and 150min-1. Three oral fluid samples were consecutively collected from a subgroup of 5 volunteers at a constant stimulation (70min-1) and at a self-selected pace to evaluate reproducibility.The urate concentration in oral fluid decreased with the increase of the stimulation and oral fluid flow rate (r=-0.98, p=0.01). Also, the lactate concentration was much (p=0.03, two tailed) lower in samples collected under a mild stimulation (50min-1) than in samples collected without stimulation. Nevertheless, it progressively increased at higher stimulations (100 and 150min-1). A transfer process mediated by membrane carriers (i.e. urate transporter and organic anion transporters) was hypothesized to explain these results. Finally, a reduced variability (relative standard deviation below 10%) of the urate concentration was obtained when oral fluid was sampled at constant stimulation (70min-1), but it increased remarkably (20-50%) in case of sampling at self-selected pace. Nevertheless, expressing the salivary excretion of urate as a function of time (?gmin-1), the variability of sampling procedure at self-selected pace was lower than 15%.
2016
Istituto di Chimica dei Composti OrganoMetallici - ICCOM -
Flow rate; Lactate; Oral fluid; PH; Sampling procedures; Uric acid
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/328430
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 37
social impact