The Frascati Tokamak Upgrade (FTU) device can operate at high electron density regimes of the order of 1020 m- 3, where the MARFE instability is present at various plasma current and magnetic field values. When the MARFE is well developed and oscillating, its movement causes continuous density fluctuation, contaminating the integral density measurements. The amplitude and frequency of these density fluctuations are well revealed by the high resolution interferometer available on FTU, the dependence of the frequency versus basic plasma parameters is investigated in this paper. A specific experimental session on FTU, including some discharges with reversed toroidal magnetic field, and pushing the plasma column towards the internal or external side of the vacuum chamber, respectively, has shown that, when the plasma column is distant from the toroidal limiter, the MARFE is stable and does not oscillate around the mid plane. For these last cases the MARFE localization with respect to the ion drift direction, which can influence the stable and unstable positions, is also discussed.

Dynamic and frequency behaviour of the MARFE instability on FTU

Spizzo G;Bin W;
2017

Abstract

The Frascati Tokamak Upgrade (FTU) device can operate at high electron density regimes of the order of 1020 m- 3, where the MARFE instability is present at various plasma current and magnetic field values. When the MARFE is well developed and oscillating, its movement causes continuous density fluctuation, contaminating the integral density measurements. The amplitude and frequency of these density fluctuations are well revealed by the high resolution interferometer available on FTU, the dependence of the frequency versus basic plasma parameters is investigated in this paper. A specific experimental session on FTU, including some discharges with reversed toroidal magnetic field, and pushing the plasma column towards the internal or external side of the vacuum chamber, respectively, has shown that, when the plasma column is distant from the toroidal limiter, the MARFE is stable and does not oscillate around the mid plane. For these last cases the MARFE localization with respect to the ion drift direction, which can influence the stable and unstable positions, is also discussed.
2017
Istituto di fisica del plasma - IFP - Sede Milano
Istituto gas ionizzati - IGI - Sede Padova
Greenwald limit
Ion drift
MARFE
Plasma radiation
Single particle motion
Tokamak
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/328688
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
social impact