A soil, a plant and a fertilizer sample were investigated by double-pulse (DP) laser-induced breakdown spectroscopy (LIBS) in orthogonal beam geometry using a reheating configuration. The DP-LIBS signal enhancement was evaluated with respect to the corresponding single-pulse (SP) LIBS as a function of the interpulse delay at various ablation energies. The maximum signal enhancement measured was 155-fold when low ablation energy (4 mJ) and an interpulse delay of 10 ?s were used. At high laser energies (>= 16 mJ) and interpulse delay of 0.6 ?s, the maximum signal enhancement was up to 3-fold. The effect of excitation energies and interpulse delays on emission line intensities was discussed in the various conditions used. The emission line enhancement measured for ionic lines was always higher than that of atomic lines. Plasma excitation temperature and electron density measured as a function of interpulse delays at various ablation energies were shown to be related to the emission line intensities.

Double-pulse laser induced breakdown spectroscopy in orthogonal beam geometry to enhance line emission intensity from agricultural samples

Senesi Giorgio S;
2017

Abstract

A soil, a plant and a fertilizer sample were investigated by double-pulse (DP) laser-induced breakdown spectroscopy (LIBS) in orthogonal beam geometry using a reheating configuration. The DP-LIBS signal enhancement was evaluated with respect to the corresponding single-pulse (SP) LIBS as a function of the interpulse delay at various ablation energies. The maximum signal enhancement measured was 155-fold when low ablation energy (4 mJ) and an interpulse delay of 10 ?s were used. At high laser energies (>= 16 mJ) and interpulse delay of 0.6 ?s, the maximum signal enhancement was up to 3-fold. The effect of excitation energies and interpulse delays on emission line intensities was discussed in the various conditions used. The emission line enhancement measured for ionic lines was always higher than that of atomic lines. Plasma excitation temperature and electron density measured as a function of interpulse delays at various ablation energies were shown to be related to the emission line intensities.
2017
Ablative energy
DP LIBS analysis
Fertilizer
Orthogonal geometry
Plant
Soil
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/330144
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 37
social impact