We describe a novel method for dynamic estimation of multi-dipole states from magneto-/electroencephalography (M/EEG) time series. The new approach builds on the recent development of particle filters for M/EEG; these algorithms approximate, with samples and weights, the posterior distribution of the neural sources at time t given the data up to time t. However, for off-line inference purposes it is preferable to work with the smoothing distribution, i.e. the distribution for the neural sources at time t conditioned on the whole time series. In this study, we use a Monte Carlo algorithm to approximate the smoothing distribution for a time-varying set of current dipoles. We show, using numerical simulations, that the estimates provided by the smoothing distribution are more accurate than those provided by the filtering distribution, particularly at the appearance of the source. We validate the proposed algorithm using an experimental data set recorded from an epileptic patient. Improved localization of the source onset can be particularly relevant in source modeling of epileptic patients, where the source onset brings information on the epileptogenic zone.

Bayesian smoothing of dipoles in magneto-/electroencephalography

2016

Abstract

We describe a novel method for dynamic estimation of multi-dipole states from magneto-/electroencephalography (M/EEG) time series. The new approach builds on the recent development of particle filters for M/EEG; these algorithms approximate, with samples and weights, the posterior distribution of the neural sources at time t given the data up to time t. However, for off-line inference purposes it is preferable to work with the smoothing distribution, i.e. the distribution for the neural sources at time t conditioned on the whole time series. In this study, we use a Monte Carlo algorithm to approximate the smoothing distribution for a time-varying set of current dipoles. We show, using numerical simulations, that the estimates provided by the smoothing distribution are more accurate than those provided by the filtering distribution, particularly at the appearance of the source. We validate the proposed algorithm using an experimental data set recorded from an epileptic patient. Improved localization of the source onset can be particularly relevant in source modeling of epileptic patients, where the source onset brings information on the epileptogenic zone.
2016
Istituto Superconduttori, materiali innovativi e dispositivi - SPIN
Bayesian inverse problems
electroencephalography
epilepsy
magnetoencephalography
particle smoothing
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/330784
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
social impact