An experimental investigation of a fluid to reconstruct the internal structure was carried out by an X-ray ?-tomography technique using a Cu K? source coupled with polycapillary optics and a CCD detector. The fluid was a transient gasoline spray generated by a multi-hole GDI injector for automotive applications at 40 MPa injection pressure and 4.0 ms duration. Measurements of mass density and droplet fragmentation in a region of few cubic millimeters downstream the injector nose are of huge importance to define the atomization process and the air/fuel mixture formation going on for the combustion. The coupling of a conventional X-ray source with polycapillary optics increased greatly the radiation flux, shaping a low-divergent beam and overcoming the relative low absorption of the hydrocarbon chain. The experimental setup is restrained in a table-top configuration contrary to the synchrotron sources generally used for these samples. Extinction images acquired along the line-of-sight source-spray-detector permitted the reconstruction of a 3D structure of the spray and its morphology. Gaussian-type distribution of the fuel densities results for the cross sections of the jets with peaks along its axis and a decreasing behavior toward the periphery.

3-D structure of a gasoline spray by polycapillary X-ray u-tomography

L Marchitto;
2017

Abstract

An experimental investigation of a fluid to reconstruct the internal structure was carried out by an X-ray ?-tomography technique using a Cu K? source coupled with polycapillary optics and a CCD detector. The fluid was a transient gasoline spray generated by a multi-hole GDI injector for automotive applications at 40 MPa injection pressure and 4.0 ms duration. Measurements of mass density and droplet fragmentation in a region of few cubic millimeters downstream the injector nose are of huge importance to define the atomization process and the air/fuel mixture formation going on for the combustion. The coupling of a conventional X-ray source with polycapillary optics increased greatly the radiation flux, shaping a low-divergent beam and overcoming the relative low absorption of the hydrocarbon chain. The experimental setup is restrained in a table-top configuration contrary to the synchrotron sources generally used for these samples. Extinction images acquired along the line-of-sight source-spray-detector permitted the reconstruction of a 3D structure of the spray and its morphology. Gaussian-type distribution of the fuel densities results for the cross sections of the jets with peaks along its axis and a decreasing behavior toward the periphery.
2017
Istituto Motori - IM - Sede Napoli
fuel spray
X-ray diagnostic
policapillary
micro-tomography
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/330867
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact