EVs from sera of representative patients with eight different HMs and healthy subjects (controls) were isolated using differential centrifugation. The identity and quality of the EVs were verified by atomic force and transmission electron microscopy. The EV miR155 levels were measured by quantitative RT-PCR. The sensitivity, specificity and area under the curve (AUC) of differences in EV miR155 levels were determined using ROC curve analyses.
MicroRNA-155 in serum-derived extracellular vesicles as a potential biomarker for hematologic malignancies - a short report
Girasole Marco;Dinarelli Simone;De Stradis Angelo;
2017
Abstract
EVs from sera of representative patients with eight different HMs and healthy subjects (controls) were isolated using differential centrifugation. The identity and quality of the EVs were verified by atomic force and transmission electron microscopy. The EV miR155 levels were measured by quantitative RT-PCR. The sensitivity, specificity and area under the curve (AUC) of differences in EV miR155 levels were determined using ROC curve analyses.File in questo prodotto:
Non ci sono file associati a questo prodotto.