In the framework of the program for the construction of 1 MeV-16 MW negative neutral beam injector (NNBI) for ITER, an R&D activity on voltage holding in vacuum has been initiated since 2009, aimed at supporting the design, construction, and development of the NNBI accelerator. For this purpose the voltage holding prediction model (VHPM) previously developed 1 has been updated. In the VHPM the effect of the electric field anode and the electric field cathode on the probability of breakdown is evaluated, by two exponents: alpha and gamma. On the basis of the experimental results from different test stands and of detailed 3D numerical simulation of the corresponding electric field configurations, the predictions of the VHPM numerical code have been benchmarked. New exponents, alpha and gamma have been proposed to obtain a more precise location of the weak point of the system and a better prediction of the maximum withstanding dc voltage in high vacuum.

Numerical-experimental benchmarking of a probabilistic code for prediction of Voltage Holding in High Vacuum, for ITER NNBI.

De Lorenzi Antonio;
2017

Abstract

In the framework of the program for the construction of 1 MeV-16 MW negative neutral beam injector (NNBI) for ITER, an R&D activity on voltage holding in vacuum has been initiated since 2009, aimed at supporting the design, construction, and development of the NNBI accelerator. For this purpose the voltage holding prediction model (VHPM) previously developed 1 has been updated. In the VHPM the effect of the electric field anode and the electric field cathode on the probability of breakdown is evaluated, by two exponents: alpha and gamma. On the basis of the experimental results from different test stands and of detailed 3D numerical simulation of the corresponding electric field configurations, the predictions of the VHPM numerical code have been benchmarked. New exponents, alpha and gamma have been proposed to obtain a more precise location of the weak point of the system and a better prediction of the maximum withstanding dc voltage in high vacuum.
2017
Istituto gas ionizzati - IGI - Sede Padova
Voltage Holding in High Vacuum
Negative Neutral Beam Injector
NNBI
ITER
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/334044
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact