Aim of this work is the dynamic simulation of the operation of a small-scale multi-generation system, based on a Solid Oxide Fuel Cell (SOFC) micro-cogenerator (?CHP) coupled to an adsorption chiller, to provide electric and cooling energy to a telecommunication shelter. The dynamic simulation model has been implemented in TRNSYS environment. The ?CHP has nominal electric power of 2.5 kW and its thermal output is used to drive a thermally driven adsorption chiller, with nominal cooling power of 10 kW. The performance of both components were experimentally validated under controlled lab conditions. The developed model allowed to optimize the system configuration and to perform an energy and environmental analysis. This analysis demonstrated the possibility of achieving global energy efficiency up to 63% with a CO2 reduction proportional to the electric and cooling load of the telecommunication shelter.

Dynamic simulation of a multi-generation system, for electric and cooling energy provision, employing a SOFC cogenerator and an adsorption chiller

Valeria Palomba;Marco Ferraro;Andrea Frazzica;Salvatore Vasta;Francesco Sergi;Vincenzo Antonucci
2017

Abstract

Aim of this work is the dynamic simulation of the operation of a small-scale multi-generation system, based on a Solid Oxide Fuel Cell (SOFC) micro-cogenerator (?CHP) coupled to an adsorption chiller, to provide electric and cooling energy to a telecommunication shelter. The dynamic simulation model has been implemented in TRNSYS environment. The ?CHP has nominal electric power of 2.5 kW and its thermal output is used to drive a thermally driven adsorption chiller, with nominal cooling power of 10 kW. The performance of both components were experimentally validated under controlled lab conditions. The developed model allowed to optimize the system configuration and to perform an energy and environmental analysis. This analysis demonstrated the possibility of achieving global energy efficiency up to 63% with a CO2 reduction proportional to the electric and cooling load of the telecommunication shelter.
2017
Istituto di Tecnologie Avanzate per l'Energia - ITAE
SOFC
adsorption chiller
telecommunication
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/335048
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact