Fast neutron detectors with a sub-centimetric space resolution are required in order to qualify neutron beams in applications related to magnetically-controlled nuclear fusion plasmas and to spallation sources . Based on the results obtained with small area prototypes, the first medium-size (20 x 35.2 cm 2 active area) nGEM detector has been realized for both the CNESM diagnostic system of the SPI DER NBI prototype for ITER and as a beam monitor for fast neutrons beam lines at spallation sources, too. Th e nGEM is a Triple GEM gaseous detector equipped with polyethylene layers used to convert fast neutrons into recoil protons through the elastic scattering process . This paper describes the performance of the medium-size nGEM detector tested at the VESUVIO beam line of the ISIS spallation source . Being this detector the actual largest area fa st neutron detector based on the GEM technology, particular attention was paid in the study of detector response in different points over the active area. Measurements of GEM counting rate (both as a function of VGEM and of time) and of the capability of the detector to reconstruct the beam in different positions are presented. This de tector serves as a basis for the realizati on of an even larger area detector that will be used in the MITICA NBI prototype for ITER that repr esents the evolution of SPIDER.

Performance of a Medium-Size Area nGEM Detector for Neutron Beam Diagnostics

Croci G;Muraro A;Grosso G;Pasqualotto R;Perelli Cippo E;Tardocchi M;
2015

Abstract

Fast neutron detectors with a sub-centimetric space resolution are required in order to qualify neutron beams in applications related to magnetically-controlled nuclear fusion plasmas and to spallation sources . Based on the results obtained with small area prototypes, the first medium-size (20 x 35.2 cm 2 active area) nGEM detector has been realized for both the CNESM diagnostic system of the SPI DER NBI prototype for ITER and as a beam monitor for fast neutrons beam lines at spallation sources, too. Th e nGEM is a Triple GEM gaseous detector equipped with polyethylene layers used to convert fast neutrons into recoil protons through the elastic scattering process . This paper describes the performance of the medium-size nGEM detector tested at the VESUVIO beam line of the ISIS spallation source . Being this detector the actual largest area fa st neutron detector based on the GEM technology, particular attention was paid in the study of detector response in different points over the active area. Measurements of GEM counting rate (both as a function of VGEM and of time) and of the capability of the detector to reconstruct the beam in different positions are presented. This de tector serves as a basis for the realizati on of an even larger area detector that will be used in the MITICA NBI prototype for ITER that repr esents the evolution of SPIDER.
2015
Istituto di fisica del plasma - IFP - Sede Milano
Istituto gas ionizzati - IGI - Sede Padova
GEM (Gas Electron Multiplier)
Fast neutrons
Medium-size area
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/336037
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact