A multifunctional lab-on-a-chip platform for spectroscopic analysis of liquid samples based on an optofluidic jet waveguide is reported. The optofluidic detection scheme is achieved through the total internal reflection arising in a liquid jet of only 150 mu m diameter, leading to highly efficient signal excitation and collection. This results in an optofluidic chip with an alignment-free spectroscopic detection scheme, which avoids any background from the sample container. This platform has been designed for multiwavelength fluorescence and Raman spectroscopy. The chip integrates a recirculation system that reduces the required sample volume. The evaluation of the device performance has been accomplished by means of fluorescence measurements performed on eosin Y in water solutions, achieving a limit of detection of 33 pM. The sensor has been applied in Raman spectroscopy of water-ethanol solutions, leading to a limit of detection of 0.18%. As additional application, analysis of riboflavin using fluorescence detection demonstrates the possibility of detecting this vitamin at the 560 pM level (0.21 ng l(-1)). Although measurements have been performed by means of a compact and low-cost spectrometer, in both cases the microjet optofluidic chip achieved similar performances if not better than high-end benchtop based laboratory equipment. This approach paves the way towards portable lab-on-a-chip devices for high sensitivity environmental and biochemical sensing, using optical spectroscopy.

Multifunctional optofluidic lab-on-chip platform for Raman and fluorescence spectroscopic microfluidic analysis

Persichetti G;Testa G;Bernini R
2017

Abstract

A multifunctional lab-on-a-chip platform for spectroscopic analysis of liquid samples based on an optofluidic jet waveguide is reported. The optofluidic detection scheme is achieved through the total internal reflection arising in a liquid jet of only 150 mu m diameter, leading to highly efficient signal excitation and collection. This results in an optofluidic chip with an alignment-free spectroscopic detection scheme, which avoids any background from the sample container. This platform has been designed for multiwavelength fluorescence and Raman spectroscopy. The chip integrates a recirculation system that reduces the required sample volume. The evaluation of the device performance has been accomplished by means of fluorescence measurements performed on eosin Y in water solutions, achieving a limit of detection of 33 pM. The sensor has been applied in Raman spectroscopy of water-ethanol solutions, leading to a limit of detection of 0.18%. As additional application, analysis of riboflavin using fluorescence detection demonstrates the possibility of detecting this vitamin at the 560 pM level (0.21 ng l(-1)). Although measurements have been performed by means of a compact and low-cost spectrometer, in both cases the microjet optofluidic chip achieved similar performances if not better than high-end benchtop based laboratory equipment. This approach paves the way towards portable lab-on-a-chip devices for high sensitivity environmental and biochemical sensing, using optical spectroscopy.
2017
Istituto per il Rilevamento Elettromagnetico dell'Ambiente - IREA
Spettroscopia Raman. fluorescenza
optofluidica
sensori
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/336735
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 28
social impact